12. CONTROL UNIT
1.0 DESCRIPTION OF THE SYNOPTIC PANEL KEYS
ON/OFF (ESC) is also used to save/exit the menus
Selection key: AUTOMATIC – MANUAL – settings menu
-
key to DECREASE the power/temperature and scroll backwards the datum selected
+ key to INCREASE the power/temperature and scroll forwards the datum selected
1.1 CAPTIONS OF THE SCREEN
Screen text
Text description
OFF
The system is shutting down, this phase lasts for about 10 minutes
ON 1020…480
Stove is in first ignition phase, pellet loading, waiting for the flame to ignite
ON 480..000
Stove is in second ignition phase, start of full combustion
Warm
-
UP
Stove is warming up
P1
-
P2
-
P3
-
P4
-
P5
Power level set
05….35°C
Temperature desired in the room where the stove is installed
CLEANING
Automatic cleaning of the crucible is running
FLAME STOP
Flame stop: the stove is not operating because it probably run out of pellets
START FAILED
Ignition failed: the stove did not start because there is no ignition
Bat1
Clock battery is dead (CR2032
-
type)
When the stove is in stand
-
by mode, the screen shows the power set and whether the stove is in MANUAL
mode or the temperature set and whether the stove is in AUTOMATIC mode.