E N G
5 . ) # ! 4 % 2 -
3 4
2.0
MANUAL AUGER FILLING
If the stove is new and it has never been ignited or if it has no pellets at all, you may need to load the pellet
conveyor (auger) again.
To activate the reload function, press + and – at the same time. RELOAD (
Ricarica
) will be displayed on the
screen. The reload function ends automatically after 240” or when you press 0/1.
3.0
IGNITION
When the stove is in stand
-
by mode, press 0/1 to start the ignition procedure.
START (start of combustion) (
Avvio
) will be displayed on the screen, together with the remaining time to
the end of the cycle; after a few control cycles and after checking the ignition of the pellets, AR (heating on)
is displayed on the screen, together with the remaining time to the end of the cycle, this phase lasts for a
few minutes, thus allowing to correctly terminate the ignition procedure and the stove exchanger to warm
up. The maximum timing is indicated on the screen, but the electronic system may shorten it according to
the data detected by the sensors.
3.1
SHUTDOWN
If you press 0/1 when the stove is on, you start the shutdown phase, which includes:
a) stopping the pellet loading
b) running out of pellets in the crucible while the smoke fan stays on (usually for 10’)
c) cooling down the stove body while the smoke fan stays on (usually for 10’)
d) displaying “OFF” on the screen, as well as the minutes to the end of the shutdown phase
During the shutdown phase it is not possible to turn the stove on again. Once the shutdown is over, the
system goes back in stand
-
by mode.
3.2
MANUAL OPERATION
The MANUAL operation mode allows to set the power to operate the stove, no matter what the
temperature of the room where it is installed may be. To select the MANUAL operation mode, press MENU
and set the power on the screen. Now press + to increase the power or – to decrease it.