36 UNIBLOC-PD Operation & Service Manual: PD200-576
PROBLEM
POSSIBLE CAUSE
SOLUTION
E. Pump is noisy
1. Cavitation.
2. Liquid contains air.
3. Discharge pressure too high.
1. See C.
2. Check pump shaft seals for
leaks. Check suction side pipe fit
-
tings for leaks. Increase NPSHA.
3. Check suction and discharge pip-
ing for closed valves or obstruc-
tions. Increase pump size.
F. Motor overheating
1. Motor size too small.
2. Discharge pressure too high.
3. Viscosity higher than
expected.
4. Motor & pump misalignment.
1. Increase motor size.
2. Lower pump speed. Lower
pressure. Check suction and
discharge piping for closed valves
or obstructions.
3. Decrease pump speed. Increase
pipe size or shorten discharge
pipe length.
4. Correct alignment.
G. Shaft seals leak
1. Loose drive collar on single
mechanical seals.
2. Worn parts.
3. Seals have been operated
without product in pump or with-
out flushing liquid.
4. Seal incompatible with liquid
1. Reset drive collars.
2. Replace seals and/or o-rings.
3. Operate pump only when liquids
Can come in contact with seals.
Replace worn seal parts.
4. Contact factory for proper seal
selection, operation, and replace
if necessary.
Summary of Contents for 54001010P20H6010T12E
Page 42: ...42 UNIBLOC PD Operation Service Manual PD200 576 UNIBLOC PUMP ...
Page 43: ...UNIBLOC PD Operation Service Manual PD200 576 43 UNIBLOC PUMP ...
Page 44: ...44 UNIBLOC PD Operation Service Manual PD200 576 UNIBLOC PUMP ...
Page 45: ...UNIBLOC PD Operation Service Manual PD200 576 45 UNIBLOC PUMP ...
Page 46: ...46 UNIBLOC PD Operation Service Manual PD200 576 UNIBLOC PUMP ...
Page 47: ...UNIBLOC PD Operation Service Manual PD200 576 47 UNIBLOC PUMP ...
Page 48: ...48 UNIBLOC PD Operation Service Manual PD200 576 UNIBLOC PUMP ...
Page 49: ...UNIBLOC PD Operation Service Manual PD200 576 49 UNIBLOC PUMP ...
Page 50: ...50 UNIBLOC PD Operation Service Manual PD200 576 3 ...
Page 51: ......
Page 52: ......