18 UNIBLOC-PD Operation & Service Manual: PD200-576
4.4.1.3 UNIBLOC 300-575 Single Mechanical Seal Removal
Loosen the
Stud Nuts (item 43 in Figure 4.4.1)
. Remove the
Rotor Housing
by pulling on the ports or by tapping gently with
a rubber mallet. Do not rock the
Rotor Housing
back and forth excessively. The seals may break. The
Seal Retaining Rings
,
the
Bolts
, the
Stationary Seal Faces
, and the
Stationary Seal O-Rings
will all come off with the
Rotor Housing
. Unscrew the
Bolts
to remove the
Seal Retaining Rings
, the
Stationary Seal Faces
, and the
Stationary Seal O-Rings
. Slide the
Rotating Seal
Faces
and the
Rotating Seal O-Rings
off the shafts. To avoid damage, handle and store the loose
Stationary Seal Faces
and
Ro-
tating Seal Faces
so that their lapped sealing surfaces do not get scratched. If not being replaced, the
Drive Collars
may remain
on the shafts, otherwise loosen the set screws and slide them off the shafts. UNIBLOC-PD 500 Series may use wear sleeves. See
section 4.4.4.1 sketch.
4.4.1.4 UNIBLOC 300-575 Single Mechanical Seal Installation
The shafts and the rotor housing bores should be cleaned before installing the seal components. Slide the
Drive Collars
on the
shafts. Moisten the
Rotating Seal O-Rings
with water or coat them with a lubricant that is acceptable for use with the product.
Slide the
Rotating Seal O-Rings
onto the shafts and then the
Rotating Seal Faces
, slotted sides first. Align the slots in the
Rotat-
ing Seal Faces
with the pins in the
Drive Collars
. Push the
Rotating Seal Faces
against the
Drive Collars
so that the
Rotating
Seal O-Rings
seat properly. Place the
Stationary Seal O-Rings
(front & outer) on the
Stationary Seal Faces
. Only lubricate
these o-rings with water or alcohol. Push the
Stationary Seal Faces
into the rotor housing so that they seat flat with the step in the
housing. Some applications require pins to be used in the
Stationary Seal Faces
. When placing them in the rotor housing align
the pins with the holes in the rotor housing and press them in. Do not use objects that will scratch the
Stationary Seal Faces’
seal
surface to push them in. Place a product compatible lubricant on the sealing surfaces. If
Seal Retaining Rings
were supplied with
the pump, bolt them to the rotor housing.
Proceed to section 4.4.7 to complete the installation
. After installing the housing push
the
Drive Collars
toward it. Compress the
Wave Springs
while leaving a 2-3mm (0.08”-0.12”) gap between the
Drive Collars
and the
Rotating Seal Faces
. Tighten the
Drive Collar
set screws. UNIBLOC-PD 500 Series may use wear sleeves. See section
4.4.4.1 sketch.
UNIBLOC-PD 300-575 with Single Mechanical Seals
Summary of Contents for 54001010P20H6010T12E
Page 42: ...42 UNIBLOC PD Operation Service Manual PD200 576 UNIBLOC PUMP ...
Page 43: ...UNIBLOC PD Operation Service Manual PD200 576 43 UNIBLOC PUMP ...
Page 44: ...44 UNIBLOC PD Operation Service Manual PD200 576 UNIBLOC PUMP ...
Page 45: ...UNIBLOC PD Operation Service Manual PD200 576 45 UNIBLOC PUMP ...
Page 46: ...46 UNIBLOC PD Operation Service Manual PD200 576 UNIBLOC PUMP ...
Page 47: ...UNIBLOC PD Operation Service Manual PD200 576 47 UNIBLOC PUMP ...
Page 48: ...48 UNIBLOC PD Operation Service Manual PD200 576 UNIBLOC PUMP ...
Page 49: ...UNIBLOC PD Operation Service Manual PD200 576 49 UNIBLOC PUMP ...
Page 50: ...50 UNIBLOC PD Operation Service Manual PD200 576 3 ...
Page 51: ......
Page 52: ......