Use the
power cord
properly
You can only use the special power cord for the instrument approved by the local
and state standards. Please check whether the insulation layer of the cord is
damaged or the cord is exposed, and test whether the cord is conductive. If the cord
is damaged, please replace it before using the instrument.
Instrument
grounding
To avoid electric shock, the grounding conductor must be connected to the ground.
This product is grounded through the grounding conductor of the power supply.
Please be sure to ground this product before it is powered on.
AC power
supply
Please use the AC power supply specified for this device. Please use the power
cord approved by your country and confirm that the insulation layer is not damaged.
Electrostatic
prevention
This device may be damaged by static electricity, so it should be tested in the
anti-static area if possible. Before the power cable is connected to this device, the
internal and external conductors should be grounded briefly to release static
electricity. The protection grade of this device is 4KV for contact discharge and 8KV
for air discharge.
Measurement
accessories
Measurement accessories are of lower class, which are definitely not applicable to
main power supply measurement, CAT II, CAT III or CAT IV circuit measurement.
Use the input
/ output port
of this device
properly
Please use the input / output ports provided by this device in a properly manner. Do
not load any input signal at the output port of this device. Do not load any signal that
does not reach the rated value at the input port of this device. The probe or other
connection accessories should be effectively grounded to avoid product damage or
abnormal function. Please refer to the product manual for the rated value of the input
/ output port of this device.
Power fuse
Please use power fuse of specified specification. If the fuse needs to be replaced, it
must be replaced with another one that meets the specified specifications (Class T,
rated current 5A, rated voltage 250V) by the maintenance personnel authorized by
UNI-T.
Disassembly
and cleaning
There are no components available to operators inside. Do not remove the
protective cover.
Maintenance must be carried out by qualified personnel.
Service
environment
This device should be used indoors in a clean and dry environment with ambient
temperature from 0
℃
to 40
℃
.
Do not use this device in explosive, dusty or humid air.
Do not
operate in
humid
environment
Do not use this device in a humid environment to avoid the risk of internal short
circuit or electric shock.