64 UTG2000B Series
First make the instrument run in BPSK mode, and then set an internal sine wave of 2kHz and 2Vpp as
carrier signal. Finally set carrier phase and initial modulation phase to be 90 ˚, frequency between phases
to be 1kHz and PN code to be PN15. The specific steps are as follows:
Use BPSK function
Press s Menu
→
Type
→
BPSK successively (press soft key Type to select if Type is not
highlighted) to use BPSK function.
Set carrier signal parameters
Press Carrier
→
Type
→
Sine to select carrier signal as sine wave. The default carrier signal is sine
wave, so it is unnecessary to change in this example.
You can press Param to setup the parameters.