8.1 All Parameters Measurement
Press the MEASURE button to enter the automatic measurement menu.
Then press F1 to select the source of the measurement . Press F2 to select
all 34 parameters.
The color of measured parameters is consistent with the current channel.
When "----" is shown, it indicates that the current source has no signal input,
or the measurement result is not valid (too big or too small).
all parameters display interface
8.2 Voltage parameters
Voltage Parameter Diagram
Vmax
:
Voltage
at
the
highest
point
with
respect
to
GND
Vmin
:
Voltage
at
the
lowest
point
with
respect
to
GND
Vtop
:
Highest
stable
voltage
Vbase
:
Lowest
stable
voltage
Middle
:
Midpoint
between
highest
and
lowest
stable
voltage
Vpp
:
Vmax
–
Vmin
Vamp
:
Vtop
–
Vbase
Mean
:
Average
amplitude
of
the
waveform
on
screen
CycMean
:
Average
amplitude
of
a
waveform
in
one
period
RMS
:
The
effective
value
.
According
to
the
energy
produced
by
the
AC
signal
in
the
conversion
,
the
equivalent
energy
that
the
DC
voltage
corresponds
to
CycRMS
:
The
RMS
of
one
period
Overshoot
:
The
ratio
of
the
difference
between
Vmax
and
Vtop
Preshoot
:
The
ratio
of
the
difference
between
Vmin
and
Vbase
Area
:
The
product
of
time
and
voltage
for
all
points
on
the
screen
CycArea
:
The
product
of
time
and
voltage
for
all
points
in
one
period
UTD2000CEX-II
User Manual
Summary of Contents for UTD2000CEX-II Series
Page 1: ...UTD2000CEX II Series Digital oscilloscope User Manual ...