29
To test for continuity, connect the Meter as below:
1.
2.
3.
Model UT805: OPERATING MANUAL
COM
Rx
F. Testing for Continuity
(See figure 10)
Warning
To avoid damages to the Meter or to the devices under
test, disconnect circuit power and discharge all the
high-voltage capacitors before testing for continuity.
To avoid harms to you, please do not attempt to input
v o l t a g e s h i g h e r t h a n 6 0 V D C o r 3 0 V A C .
Insert the red test lead into the terminal
and the black test lead into the
COM
terminal.
Press button to enter continuity measurement
mode.
Connect the test lead across with the object being
measured.
The buzzer sounds if the resistance of a circuit under
test is < 25 , the circuit is in good condition. The
primary display shows the reading of the tested
resistor and the secondary displays shows 600.0
range.
(figure 10)