Model DMM7512 7½ Digit Sampling Multimeter 

Instrument Information 

071357601 / October 2018 

*P071357601*

Introduction 

This document describes the DMM7512 7½ Digit Multimeter instrument and how it differs from the Model 

DMM

7510 7½ Digit Multimeter instrument.

The DMM7512 is a no-front-panel version of the DMM7510 that has two DMM modules housed in one 

enclosure. Except for the power switch, each module operates independently within the enclosure. 

Figure 1: DMM7512 7½ Digit Multimeter 

What you should have received 

In addition to the DMM7512, you should have received the items in the following table. 

Part number 

Description 

Quantity 

012178100 

Test lead kit 

CA-180-16A 

LAN crossover cable, 16 in. 

1747107

XX

 

Shielded crossover cable with RJ-45 connector, 5 ft. 

CO-26 

Power line cord 

CS-568-120A 

Green and yellow ground cable, 120 in. 

0713411

XX

 

Safety precautions 

4299-13 Rack Mount kit, consisting of: 

4076126

XX

 

1U rack rail mount 

10-32X3/8PHTRSH

10-32X3/8 Phillips truss head screw

10-32X5/8PHTRSH

10-32X5/8 Phillips truss head screw

FA-274 

Cage nut 

Note: 

XX

 is the latest revision number. 

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com 

Summary of Contents for DMM7512

Page 1: ...ave received In addition to the DMM7512 you should have received the items in the following table Part number Description Quantity 012178100 Test lead kit 4 CA 180 16A LAN crossover cable 16 in 2 1747...

Page 2: ...Provides application examples that you can use as a starting point to create your own applications The Model DMM7510 7 Digit Graphical Sampling Multimeter Calibration and Adjustment Manual Provides c...

Page 3: ...tions are on the rear panel of the instrument only There is no front terminal or rear terminal selection See Rear panel overview on page 6 for locations The instrument dimensions are different and the...

Page 4: ...ling Multimeter Instrument Information 4 071357601 October 2018 Dimensions The following figures show the mounting screw locations and other dimensions of the instrument Figure 2 DMM7512 top view Figu...

Page 5: ...port USB Type A connection You can use a USB flash drive to store reading buffer data scripts and user setups You can also use it to upgrade the firmware LAN RESET Reverts the LAN settings and the in...

Page 6: ...etwork The DMM7512 is a version 1 5 LXI Device Specification 2016 instrument that supports TCP IP and complies with IEEE Std 802 3 ethernet LAN See Setting up remote communications on page 7 Rear pane...

Page 7: ...r outlet The line fuse located just above the power receptacle protects the power line input of the instrument Setting up remote communications Each device on a LAN corporate or private requires a uni...

Page 8: ...d This allows remote access to LXI web page controls that may have been password protected before the reset To use the LAN RESET switch to select Automatic configuration 1 Turn on instrument power 2 W...

Page 9: ...e web interface and virtual front panel 1 Open a web browser on the host computer 2 Enter the IP address of the module in the address box of the web browser For example the default address for module...

Page 10: ...Fuse replacement To prevent injury death or instrument damage use only the correct fuse type see table To replace the line fuse 1 Power off the instrument and remove the line cord 2 There is a small t...

Page 11: ...ibration and adjustment using USB or LAN connection methods You can use the methods described in Adjustment command timing and error checking in the Calibration and Adjustment Manual Due to the heavie...

Page 12: ...y be connected to mains These instruments will be marked as category II or higher Unless explicitly allowed in the specifications operating manual and instrument labels do not connect any instrument t...

Page 13: ...mentation explains hazards that could damage the instrument Such damage may invalidate the warranty The CAUTION heading with the symbol in the user documentation explains hazards that could result in...