27
1.
2.
3.
Model UT805: OPERATING MANUAL
COM
E. Testing Diodes
(See figure 9)
Warning
To avoid possible damage to the Meter and to the
device under test, disconnect circuit power and
discharge all high-voltage capacitors before testing
diodes.
To avoid harms to you, please do not attempt to input
v o l t a g e s h i g h e r t h a n 6 0 V D C o r 3 0 V A C .
Use the diode test to check diodes, transistors, and
other semiconductor devices. The diode test sends a
current through the semiconductor junction, and then
measures the voltage drop across the junction. A good
silicon junction drops between 0.5V and 0.8V.
To test a diode out of a circuit, connect the Meter as
follows:
Insert the red test lead into terminal and
the black test lead into the
COM
terminal.
Press button to enter diode measurement mode.
For forward voltage drop readings on any
semiconductor component, place the red test lead
(figure 9)
Summary of Contents for UT805