background image

7

8

1.3.2 Current Specifications

UT512D

±

(

10%+5

)

0.01nA~3.50mA

UT512E

0.01nA~5.00mA

0.01nA
0.01µA

0.01mA

Model

Measurement accuracy Display accuracy

Range

Remark

Test stops 
automatically if 
current remains 
at ≥1.00mA for 10s

1.3.3 Output Voltage Specifications

250V

+

(

0%

~

20

)

%

250V

300V

1V

500V

1000V

2500V

500V

600V

1000V

1200V

2500V

3000V

Rated voltage

Output accuracy

Display accuracy

Output voltage

Remark

Voltage adjustment 
range with step set 
at 10%: 
(50%~120%)
250V cannot step 
down and 2500V 
cannot step up.

1.3.4 Voltage Testing Specifications

30

1000VDC

1V

±(3%+5)

1V

±(3%+5)

30

750VAC

OL

OL

Voltage 
measurement

Measurement 
range

Accuracy

Resolution

Over-range 
indication

Remark

1. Input impedance: 
    200MΩ
2. Frequency:  
    50Hz/60Hz

DC voltage

AC voltage

Note: LO is displayed if the input voltage is less than about 25V; the reading flashes if the input 
voltage is between about 750VAC~824VAC or 1000VDC~1099VDC; “OL” is displayed with buzzer 
making sound and LCD flashing if the input voltage is greater than about 1100VDC or about 825VAC.

0.01uF~2.00uF

±(15%+3)

0.1Ω~600Ω

±(2%+10)      

1.3.5 Capacitance Testing Specifications (UT512E)

Function

Measurement range

Accuracy

Remark

Capacitance 
measurement

Note the withstand voltage of 
capacitance (≤1000V)

Note: Rated voltages for capacitance measurement include 250V, 500V, and 1000V. LO is displayed 
if measured capacitance is < 0.01uF; OL is displayed if measured capacitance is >2.20uF. If capacitance 
over 2.2uF is measured when the battery power indicator shows one “segment” of lower left, the tester 
may enable battery protection, in such case, please charge the tester to activate the battery.

1.3.6 Low Resistance Testing Specifications (UT512E)

Function

Measurement range

Accuracy

Remark

Low resistance 
measurement

Open-circuit voltage: 5V

Note: If the measured resistance is ≤20Ω, the buzzer alarms; if >660Ω, “>660Ω” is displayed. 
The short-circuit current is >200mA.

1.3.7 Common Specifications

14.8V/5200mAh rechargeable lithium battery (UT512E); 
8 PCS LR14 alkaline batteries (UT512D)  

250V, 500V, 1000V, 2500V

+ (0% 20%)

~

UT512D 0.25MΩ~1.00TΩ; UT512E:0.25MΩ~2.50TΩ

UT512D: About 3.5mA (10s); UT512E: About 5.0mA (10s)

√ (default mode)

√ (automatic display)

√ (automatic display)

DC 30V~1000V; Accuracy: ±(3%+5) 
AC 30V~750V; Accuracy: ±(3%+5)

Range: 0.01uF~2.00uF; Accuracy: ±(15%+3)

Range: 0.1Ω~600Ω; Accuracy: ±(2%+10)

Current is displayed when measuring insulation resistance.

10% of the range. Range: 50%~120%

Record testing time automatically. 
Timing range: 0s~99m and 59s.

The danger warning symbol flashes 
if safety voltage is exceeded.

Store 999 groups of data

Upload testing data to computer (one-way) via USB cable.

Indicate charging or replacing battery when low battery occurs.

Power off automatically 15 minutes after the tester powers 
on(without occurrence of high voltage and operation).

Monitor the voltage of measured object and the discharge 
state after testing. If voltage is higher than 36V, it is forbidden 
to test for protecting the tester and the operator.

Power supply

Rated voltage

Output voltage accuracy

Insulation resistance range

Output short-circuit current

Continuous insulation 
resistance measurement

Polarization index testing

Absorption ratio testing

Timing measurement

Resistance comparison 

measurement

Voltage testing

Capacitance testing (UT512E)

Low resistance testing (UT512E)

Current display

Voltage stepping

Monitoring live voltage of 
external measured object

Timer testing

High voltage alarm

Storage function

Communication function

Battery power indication

Auto power off

UT512D/E User Manual

UT512D/E User Manual

Summary of Contents for UT512D

Page 1: ...UT512D UT512E 2 5kV Insulation Resistance Tester User Manual P N 110401111817X...

Page 2: ...Trend guarantees that the product is free from any defect in material and workmanship within one year from the purchase date This warranty does not apply to damages caused by accident negligence misu...

Page 3: ...ainly used to measure insulation resistance of cable motor power generator transformer mutual inductor high voltage switch lightning arrester and more it is an ideal measurement meter for electric pow...

Page 4: ...T512E 8 PCS LR14 alkaline batteries UT512D Error limit a of reading b digits one year warranty Environment temperature 23 5 Environment humidity 45 75 RH In the table below The humidity must be less t...

Page 5: ...ications UT512E Function Measurement range Accuracy Remark Low resistance measurement Open circuit voltage 5V Note If the measured resistance is 20 the buzzer alarms if 660 660 is displayed The short...

Page 6: ...bidden to use the tester without battery cover set in place otherwise it may pose a risk of electric shock Keep fingers behind the finger guard when perform measurement do not touch exposed wire conne...

Page 7: ...plug red lead GUARD Grounding protection outlet single plug green lead EARTH High resistance measurement outlet single plug black lead LCD segmented display screen Functional buttons USB port Carryin...

Page 8: ...testing Bluetooth Insulation resistance measurement mode AC DC voltage measurement mode Power on off Increase select high range or previous group of data Decrease adjust time and resistance cyclically...

Page 9: ...ress this button to switch to insulation resistance testing function V UT512E AC DC voltage testing button Without high voltage output short press V button to switch to AC DC voltage testing mode The...

Page 10: ...measurement Data deletion button In READ state short press CLR and then press ENTER to delete current data press ESC to exit data deletion function In READ state the symbol CLR and the storage capaci...

Page 11: ...rged if low battery occurs please replace with battery in same type 9 2 Battery Charging UT512E When charging with battery charger in power on state the battery power indicator and the charging symbol...

Page 12: ...hange Press TEST to perform test the LCD shows basic elements including battery power high voltage warning symbol leakage current real time output voltage measured insulation resistance testing value...

Page 13: ...tion resistance in Time1 9 3 1 4 Dielectric Absorption Ratio Measurement Dielectric Absorption Ratio DAR refers to the value of insulation resistance in 1 minute to that in 15 seconds It takes 1 minut...

Page 14: ...s if insulation resistance is less than comparison resistance the symbol FAIL will appear on the LCD otherwise PASS appears To return to the continuous measurement interface please press COMP in COMP...

Page 15: ...ltage input the danger symbol flashes in such case do not press the test button to measure resistance as shown in figure 9 3 4 2 Under resistance measurement function connect the black grounding lead...

Page 16: ...rminal with the exterior conductor of inner insulation layer and the unused cable Surface leakage current is conducted to the safety terminal so as to eliminate the surface leakage current at the meas...

Page 17: ...Red XI Maintenance Clean the casing 1 Wipe the surface using soft cloth or sponge dipped with water 2 Do not immerse the tester in water to avoid tester damage 3 Do not store the tester if it is wet 4...

Reviews: