background image

 

7

 / 

14

 

 

 
 

 
 

 
 

 
 

2. Introduction of UPO1000CS Series Digital Phosphor Oscilloscope 

UPO1000CS series contains the following 2 models.

 

 

Model 

Analog Channels 

Bandwidth 

UPO1202CS 

200MHz 

UPO1102CS 

100MHz 

3. Getting Started Guide 

This chapter introduces on using the oscilloscope for the first time, the front and rear panels, the user 

interface, as well as the built-in help system. 

 

3.1 General Inspection 

It is recommended to inspect the instrument follow the steps below before using the UPO1000CS series 

for the first time. 

(1) Check for Damages Caused by Transport 

If the packaging carton or the foam plastic cushions are severely damaged, please contact the UNI-T 

distributor of this product immediately.   

(2) Check Attachment 

Please  check  appendix  for  the  list  of  accessories.  If  any  of  the  accessories  are  missing  or  damaged, 

please contact UNI-T or local distributors of this product. 

(3) Machine Inspection 

If the instrument appears to be damaged, not working properly, or has failed the functionality test, please 

contact UNI-T or local distributors of this product. 

 

If  the  equipment  is  damaged  due  to  shipping,  please  keep  the  packaging  and  notify  both  the 

transportation department and UNI-T distributors.

 

Summary of Contents for UPO1000CS Series

Page 1: ...UPO1000CS SeriesDigital Phosphor Oscilloscope Quick Start Guide REV 1 2022 11 7...

Page 2: ...re protected by patent rights in China and foreign countries including issued and pending patents UNI T reserves the rights to any product specification and pricing changes UNI T reserves all rights L...

Page 3: ...oceed to the next step until you fully understand and meet the conditions stated in the Warning statement Caution Caution indicates the presence of a hazard It reminds users to pay attention to a cert...

Page 4: ...away from CAT IV circuit CAT III Primary circuit of large equipment directly connected to the distribution board and circuit between the distribution board and the socket three phase distributor circ...

Page 5: ...ly Please be sure to ground this product before it is powered on AC power supply Please use the AC power supply specified for this device Please use the power cord approved by your country and confirm...

Page 6: ...ersonnel of UNI T for testing Any maintenance adjustment or parts replacement must be done by the relevant personnel of UNI T Cooling Do not block the ventilation holes at the side and back of this de...

Page 7: ...r the first time 1 Check for Damages Caused by Transport If the packaging carton or the foam plastic cushions are severely damaged please contact the UNI T distributor of this product immediately 2 Ch...

Page 8: ...nter the normal interface 3 Connect Probe Use probe in the attachment and connect it BNC terminal to the channel 1 BNC terminal of the oscilloscope Connect the probe s main alligator clip to the Compe...

Page 9: ...yed waveforms Excessive Compensation Correct Compensation Insufficient Compensation Figure 2 Compensating Calibration of Probe If the displayed waveform is look like the above Insufficient Compensatio...

Page 10: ...r input terminal 2 Multipurpose knob 9 Horizontal control area 3 Function menu 10 Analog channel input terminal 4 Run Stop Automatic setting 11 Vertical control area 5 Trigger control 12 Control menu...

Page 11: ...11 14 5 Rear Panel Figure 4 Rear Panel Table 2 Description of Rear Panel NO Description NO Description 1 USB Device interface 3 Pass Fail output terminal 2 LAN interface 4 Safety lock 1 2 3 4...

Page 12: ...scale 10 LAN identification 3 Sampling rate Storage depth 11 USB host identification 4 Waveform identification 12 MATH state identification 5 Trigger position 13 CH2 state identification 6 Horizontal...

Page 13: ...trol modes a User defined programming b Use PC software instrument manager c Web Control 9 Troubleshooting 1 When press the soft power button the oscilloscope is blank screen a Check whether the power...

Page 14: ...ger level exceeds the waveform range b If it exceeds set the trigger level to the middle or set the mode to AUTO c Press AUTO button could automatically finish the above setting 6 Waveform refresh is...

Reviews: