environment-friendly use period of this product is 40 years, during which it can be 

used safely. Upon expiration of this period, it should enter the recycling system.   

Safety Requirements 

Warning 

 

Preparation before use 

Please connect this device to AC power supply with the power cable provided; 

The AC input voltage of the line reaches the rated value of this device. See the 

product manual for specific rated value. 

The line voltage switch of this device matches the line voltage; 

The line voltage of the line fuse of this device is correct. 

Check all terminal 

rated values 

Please check all rated values and marking instructions on the product to avoid fire 

and impact of excessive current. Please consult the product manual for detailed rated 

values before connection. 

Use the power cord 

properly 

You can only use the special power cord for the instrument approved by the local and 

state standards. Please check whether the insulation layer of the cord is damaged or 

the cord is exposed, and test whether the cord is conductive. If the cord is damaged, 

please replace it before using the instrument. 

Instrument Grounding 

To avoid electric shock, the grounding conductor must be connected to the ground. 

This product is grounded through the grounding conductor of the power supply. 

Please be sure to ground this product before

 

it is powered on. 

AC power supply 

Please use the AC power supply specified for this device. Please use the power cord 

approved by your country and confirm that the insulation layer is not damaged. 

Electrostatic 

prevention 

This device may be damaged by static electricity, so it should be tested in the anti-

static area if possible. Before the power cable is connected to this device, the internal 

and external conductors should be grounded briefly to release static electricity. The 

protection grade of this device is 4KV for contact discharge and 8KV for air 

discharge. 

Measurement 

accessories 

Measurement accessories are of lower class, which are definitely not applicable to 

main power supply measurement, CAT II, CAT III or CAT IV circuit measurement. 

Use the input / output 

port of this device 

properly 

Please use the input / output ports provided by this device in a properly manner. Do 

not load any input signal at the output port of this device. Do not load any signal that 

does not reach the rated value at the input port of this device. The probe or other 

connection accessories should be effectively grounded to avoid product damage or 

abnormal function. Please refer to the product manual for the rated value of the input 

/ output port of this device. 

Power fuse 

Please use power fuse of specified specification. If the fuse needs to be replaced, it 

must be replaced with another one that meets the specified specifications (Class T, 

Summary of Contents for UPO1000CS Series

Page 1: ...UPO1000CS SeriesDigital Phosphor Oscilloscope Quick Start Guide REV 1 2022 11 7...

Page 2: ...re protected by patent rights in China and foreign countries including issued and pending patents UNI T reserves the rights to any product specification and pricing changes UNI T reserves all rights L...

Page 3: ...oceed to the next step until you fully understand and meet the conditions stated in the Warning statement Caution Caution indicates the presence of a hazard It reminds users to pay attention to a cert...

Page 4: ...away from CAT IV circuit CAT III Primary circuit of large equipment directly connected to the distribution board and circuit between the distribution board and the socket three phase distributor circ...

Page 5: ...ly Please be sure to ground this product before it is powered on AC power supply Please use the AC power supply specified for this device Please use the power cord approved by your country and confirm...

Page 6: ...ersonnel of UNI T for testing Any maintenance adjustment or parts replacement must be done by the relevant personnel of UNI T Cooling Do not block the ventilation holes at the side and back of this de...

Page 7: ...r the first time 1 Check for Damages Caused by Transport If the packaging carton or the foam plastic cushions are severely damaged please contact the UNI T distributor of this product immediately 2 Ch...

Page 8: ...nter the normal interface 3 Connect Probe Use probe in the attachment and connect it BNC terminal to the channel 1 BNC terminal of the oscilloscope Connect the probe s main alligator clip to the Compe...

Page 9: ...yed waveforms Excessive Compensation Correct Compensation Insufficient Compensation Figure 2 Compensating Calibration of Probe If the displayed waveform is look like the above Insufficient Compensatio...

Page 10: ...r input terminal 2 Multipurpose knob 9 Horizontal control area 3 Function menu 10 Analog channel input terminal 4 Run Stop Automatic setting 11 Vertical control area 5 Trigger control 12 Control menu...

Page 11: ...11 14 5 Rear Panel Figure 4 Rear Panel Table 2 Description of Rear Panel NO Description NO Description 1 USB Device interface 3 Pass Fail output terminal 2 LAN interface 4 Safety lock 1 2 3 4...

Page 12: ...scale 10 LAN identification 3 Sampling rate Storage depth 11 USB host identification 4 Waveform identification 12 MATH state identification 5 Trigger position 13 CH2 state identification 6 Horizontal...

Page 13: ...trol modes a User defined programming b Use PC software instrument manager c Web Control 9 Troubleshooting 1 When press the soft power button the oscilloscope is blank screen a Check whether the power...

Page 14: ...ger level exceeds the waveform range b If it exceeds set the trigger level to the middle or set the mode to AUTO c Press AUTO button could automatically finish the above setting 6 Waveform refresh is...

Reviews: