background image

 

6

 / 

14

 

 

rated current 5A, rated voltage 250V) by the maintenance personnel authorized by 

UNI-T. 

Disassembly and 

cleaning 

There are no components available to operators inside. Do not remove the protective 

cover.   

 

Maintenance must be carried out by qualified personnel. 

Service environment 

This device should be used indoors in a clean and dry environment with ambient 

temperature from 0 

  to 40 

.   

Do not use this device in explosive, dusty or humid air. 

Do not operate in 

humid environment 

Do not use this device in a humid environment to avoid the risk of internal short 

circuit or electric shock. 

Do not operate in 

flammable and 

explosive environment 

Do not use this device in a flammable and explosive environment to avoid product 

damage or personal injury. 

Caution 

 

Abnormity 

If this device may be faulty, please contact the authorized maintenance personnel of 

UNI-T for testing. Any maintenance, adjustment or parts replacement must be done 

by the relevant personnel of UNI-T. 

Cooling 

Do not block the ventilation holes at the side and back of this device; 

Do not allow any external objects to enter this device via ventilation holes; 

Please ensure adequate ventilation, and leave a gap of at least 15 cm on both sides, 

front and back of this device. 

Safe transportation 

Please transport this device safely to prevent it from sliding, which may damage the 

buttons, knobs or interfaces on the instrument panel. 

Proper ventilation 

Poor ventilation will cause the device temperature to rise, thus causing damage to 

this device. Please keep proper ventilation during use, and regularly check the vents 

and fans. 

Keep clean and dry 

Please take actions to avoid dust or moisture in the air affecting the performance of 

this device. Please keep the product surface clean and dry. 

Note 

 

Calibration 

The recommended calibration period is one year. Calibration should only be carried 

out by qualified personnel. 

 
 
 
 
 
 
 

Summary of Contents for UPO1000CS Series

Page 1: ...UPO1000CS SeriesDigital Phosphor Oscilloscope Quick Start Guide REV 1 2022 11 7...

Page 2: ...re protected by patent rights in China and foreign countries including issued and pending patents UNI T reserves the rights to any product specification and pricing changes UNI T reserves all rights L...

Page 3: ...oceed to the next step until you fully understand and meet the conditions stated in the Warning statement Caution Caution indicates the presence of a hazard It reminds users to pay attention to a cert...

Page 4: ...away from CAT IV circuit CAT III Primary circuit of large equipment directly connected to the distribution board and circuit between the distribution board and the socket three phase distributor circ...

Page 5: ...ly Please be sure to ground this product before it is powered on AC power supply Please use the AC power supply specified for this device Please use the power cord approved by your country and confirm...

Page 6: ...ersonnel of UNI T for testing Any maintenance adjustment or parts replacement must be done by the relevant personnel of UNI T Cooling Do not block the ventilation holes at the side and back of this de...

Page 7: ...r the first time 1 Check for Damages Caused by Transport If the packaging carton or the foam plastic cushions are severely damaged please contact the UNI T distributor of this product immediately 2 Ch...

Page 8: ...nter the normal interface 3 Connect Probe Use probe in the attachment and connect it BNC terminal to the channel 1 BNC terminal of the oscilloscope Connect the probe s main alligator clip to the Compe...

Page 9: ...yed waveforms Excessive Compensation Correct Compensation Insufficient Compensation Figure 2 Compensating Calibration of Probe If the displayed waveform is look like the above Insufficient Compensatio...

Page 10: ...r input terminal 2 Multipurpose knob 9 Horizontal control area 3 Function menu 10 Analog channel input terminal 4 Run Stop Automatic setting 11 Vertical control area 5 Trigger control 12 Control menu...

Page 11: ...11 14 5 Rear Panel Figure 4 Rear Panel Table 2 Description of Rear Panel NO Description NO Description 1 USB Device interface 3 Pass Fail output terminal 2 LAN interface 4 Safety lock 1 2 3 4...

Page 12: ...scale 10 LAN identification 3 Sampling rate Storage depth 11 USB host identification 4 Waveform identification 12 MATH state identification 5 Trigger position 13 CH2 state identification 6 Horizontal...

Page 13: ...trol modes a User defined programming b Use PC software instrument manager c Web Control 9 Troubleshooting 1 When press the soft power button the oscilloscope is blank screen a Check whether the power...

Page 14: ...ger level exceeds the waveform range b If it exceeds set the trigger level to the middle or set the mode to AUTO c Press AUTO button could automatically finish the above setting 6 Waveform refresh is...

Reviews: