USER MANUAL - URS600CE AND URS600CESS JULY 2019
23
4. Maintenance
6
WARNING
If the URS600CE is in operation, first follow the steps in chapter 2.4-
2.5 for a 'Safe shutdown'. Then, unplug or disconnect the power cord
from the receptacle or switch off and “lock out” the breaker before all
maintenance and service work.
Please note!
Only use original spare parts for maintenance and repairs.
Ensure that the warning labels and the lights on the URS600CE are clearly visible at all times so that they
can alert the URS600CE users to safe use.
Please note!
Never repair the URS600CE yourself, use a recognized expert for this. Please contact your
supplier. If returning your URS600CE for repair, the distillation tank must be empty, otherwise your solvent
recycler cannot be repaired.
4.1. Periodic
maintenance
Before each use:
• Keep the area around the URS600CE is clean and free of debris.
• Check the outside and inside of the URS600CE for visible damage. Do not turn on the URS600CE if
you have detected any damage.
• Check the lid gasket for damage. A damaged lid gasket leads to poor sealing and vapour leakage
which is dangerous and wasteful.
• Inspect the condenser at the back of the unit. Clean the condenser if necessary. Refer to section 4.2
‘cleaning the condenser’.
• Make sure the unit is at least 15 cm from the wall for unobstructed ventilation.
• Check the tank for residue and remove it.
• Wipe the top surface of the tank before closing the lid and make sure it is free from paint and
contaminated solvent.
Every month:
• Inspect the power cord for wear and damage. If replacement is necessary, use only a proper cord
(according to European specification H05 VVF 3G 2.5 - this cable may not be longer than 3 meters
according to the ATEX requirements) and the replacement should be carried out by a competent
installer for ATEX equipment.
• Clean the condenser: refer to section 4.2 'cleaning the condenser'.
• Clean the vapour outlet fitting. Refer to section 'Cleaning the vapour outlet fitting’ of this manual.
Every 3 months:
• Run two recycling processes with 20 litres of clean solvent to keep the vapour outlet fitting and the
condenser clean.
Every 6 months:
• Replace the lid gasket preventively.
Every year:
• Have the URS600CE serviced and inspected annually by an expert. In addition, make sure that the
URS600CE is always in good condition. Please contact youir supplier for this.
WARNING