background image

USER MANUAL - URS600CE AND URS600CESS                                                                                                                  JULY 2019

25

4.  Install the new lid gasket by hand, by gradually pressing the ring all the way around with your fingers. 

It is important that the ring is placed flat and no deformations are visible. 

This can be checked by the horizontal seam on the ring, which must be straight along its entire length. 

Do not use tools or sharp objects while installing the new lid gasket as they may damage the gasket. 

You have replaced the lid gasket.

5.  In order to check the proper functioning of the lid gasket, it is advised to recycle the tank once with   

about 10 litres of clean water.

4.4.  Cleaning the vapour outlet fitting

A blockage in the vapour outlet fitting can cause solvent to leak out of the URS600CE. 

1.  Unscrew the vapour outlet tube. This can be loosened by hand. If this doesn’t work, carefully use a 

water pump pliers. 

Vapour outlet 

fitting

Cap from the 

vapour outlet 

fitting

Figure 12.  The vapour outlet fitting with cap

2.  Check the vapour outlet fitting and the opening of the vapour outlet fitting for visible signs of blockage. 

Vapour outlet 

fitting

Opening of the 

vapour outlet

Figure 13. 

 The vapour outlet fitting 

Summary of Contents for URS600CE

Page 1: ...S600CE European directive 2014 34 EU CE1180 ECEx BAS11 0057 Baseefa11ATEX0118 Ex db ib A T2 Gb 2G USER MANUAL Uni ram Corporation 381 Bentley St Markham ON L3R 9T2 uniram com MODELS URS600CE URS600CES...

Page 2: ...licable to both versions and talks about the machine with the generic term URS600CE Be sure to read and understand this manual completely before you start using the URS600CE If your URS600CE does not...

Page 3: ...duct overview 10 1 11 Overview of Safety Labels 11 1 12 Supplied accessories 12 1 13 Overview of the control panel 12 1 14 Safety provisions in the URS600CE 12 1 15 Name plate 13 1 16 Serial Number 14...

Page 4: ...ndling the waste and recycled solvent 22 3 8 Cleaning the tank and lid 22 3 9 Check the lid gasket and replace if necessary 22 4 Maintenance 23 4 1 Periodic maintenance 23 4 2 Cleaning the condenser 2...

Page 5: ...he URS600CE safely and establish safe working procedures considering the risks associated with the environment The following safety symbols are used in this manual 6 DA NGER Indicates that serious inj...

Page 6: ...the boiling temperature When the temperature drops below 50 C the cooling fan stops and the FAN LED light goes out Only then has the machine cooled down sufficiently such that the safety cover and the...

Page 7: ...safe situation with leakage as a result Check the tank after each cycle In case of excessive corrosion contact the service repair department of Uni ram Corporation Please note Make sure you always hav...

Page 8: ...cleaning processes used by lacquer ink processing companies Place the machine in a well ventilated and safe ATEX room without potential sources of ignition based on the international standard EN 6007...

Page 9: ...of the process these waste materials which are collected in the liner bag can be disposed of in accordance with local regulations Safety cover Tank lid Condenser discharge pipe Tank Condenser Heating...

Page 10: ...9 10 1 10 Product overview Figure 2 Overview of components of the URS600CE Description 1 Lid 2 Lid clamp 3 Bag holder 4 Tank 5 Housing 6 Door 7 Safety cover 8 Lid gasket 9 Liner bag 10 Control panel 1...

Page 11: ...S600CE must be connected either to an explosion proof ATEX receptacle using an ATEX explosion proof plug or by direct connection to an explosion proof switch that is suitable for ATEX zone 1 2 gas gro...

Page 12: ...light is on when the cooling fan is running 6 DANGER Never open the safety cover and the tank lid when the HEAT and or FAN light are on The tank has sufficiently cooled when the fan light has gone off...

Page 13: ...of the tank lid and in the case of blockage or leakage sweating ensures that the user does not directly come into contact with hot solvent vapours The safety thermostat on the tank switches off the po...

Page 14: ...he serial number of the URS600CE can be found on the silver label on the back of the cabinet Make a note of the serial number and refer to it in communications on service matters At the back of this m...

Page 15: ...he international standard EN 60079 10 1 2009 classification of hazardous areas with regard to risk of explosions Please note that recycled solvent in the receiving container in the cabinet of the URS6...

Page 16: ...nection to an explosion proof switch that is suitable for ATEX zone 1 2 gas group IIA in accordance with the ATEX installation standard EN 60079 14 9 Use the ATEX expert to connect the ring terminal o...

Page 17: ...See section 4 3 Replacing the lid gasket and 4 4 Cleaning the vspour outlet tube for instructions 6 In order to check the proper functioning of the URS600CE it is advisable to recycle about 10 litres...

Page 18: ...rature of the solvent is higher than 280 C The solvent has recently been contaminated stagnant solvent can be acidic The solvent is suitable for distillation Check the material Safety Data Sheet SDS f...

Page 19: ...of the bag all the way around over the ring Please note Ensure that the liner bag does not block the vapour outlet fitting of the tank You have now placed the liner bag step 5 step 6 step 7 step 8 Fig...

Page 20: ...he URS600CE Please note Always use the supplied HDPE pail with the 3 0 cm opening The small opening limits the possible formation of vapour to a minimum Please note Do not recycle paint remover and cl...

Page 21: ...he temperature follow these steps 1 Make sure the HEAT and FAN LED lights are off 2 Press and hold the OFF button Press the ON button several times until the desired setting is selected 3 Release the...

Page 22: ...y with a dry cloth 3 Clean the lid and the top of the tank where the lid sits and dry with a dry cloth This prolongs the life of the lid gasket and prevents leakages Avoid turning the lid during clean...

Page 23: ...vapour leakage which is dangerous and wasteful Inspect the condenser at the back of the unit Clean the condenser if necessary Refer to section 4 2 cleaning the condenser Make sure the unit is at leas...

Page 24: ...4 6 Fault codes of this manual for instructions when these errors are indicated To clean the condenser the dust can be blown away with an air gun or by using a vacuum cleaner with a brush attachment...

Page 25: ...order to check the proper functioning of the lid gasket it is advised to recycle the tank once with about 10 litres of clean water 4 4 Cleaning the vapour outlet fitting A blockage in the vapour outle...

Page 26: ...upply of power from the building to the URS600CE Check the breaker at the panel of the building and ensure that 200 240V AC single phase voltage is being supplied The problem is not due to a lack of p...

Page 27: ...during the recycling process There is a leak of solvent under the edge of the safety cover or there is more vapour than usual in the room Follow the steps from section 2 3 Safe switch off Cause Solut...

Page 28: ...solvent present between the liner bag and the distillation tank The waste material reacts with the bag and damages the bag Turn on the URS600CE on for 5 minutes and lift the bag out when it is still...

Page 29: ...circuit Contact the service repair department of Uni ram Corporation 12 1x 2x The thermocouple of the condenser has an open circuit Contact the service repair department of Uni ram Corporation 13 1x 3...

Page 30: ...switch the URS600CE on briefly The fan motor should switch on If these steps have been completed without problems run a test cycle with 15 litres of clean water to test whether the problem has been f...

Page 31: ...C 10 or LB900C 100 Retainer Ring for liner bag 770 9110 Lid Gasket 770 2150N 5 Technical properties Model URS600CE Power supply voltage frequency AC 200 240V 1 phase 50 60 Hz Current 6 01 9 79 Amperes...

Page 32: ...E Part number URS600CE Model URS600CE Length 48 cm Width 48 cm Height 115 cm Weight 46 kg Tank capacity 20 litres IP classification IP20 Lid gasket Neoprene Drainage system for solvents No Receiving c...

Page 33: ...USER MANUAL URS600CE AND URS600CESS JULY 2019 33...

Reviews: