background image

UNI-Geräte E. Mangelmann Elektrotechnische Fabrik GmbH 

Holtumsweg 13, D-47652 Weeze, Tel. +49 2837/9134-0, Fax. +49 2837/1444 

www.uni-geraete.de  [email protected] 

Seite  8/9 

TM 4021 

220.100.040-09 

 

 
 

 

Solenoid Drive 

 

Series MG…X, MG…-A.X 

 

With  - protection for intended use in ex- zone 1 
 in accordance with 2014/34/EU (ATEX 95) 

 

 

 

Technical data 

 

Explosion protection: 

 

 

 
 

II 2 G   Ex de IIC T5 Gb 

 

 

II 2 D   Ex tb IIIC T95C Db IP65 

Protective system: 

 

 IP65 

Max. temperature of housing:   

 95°C 

Ambient temperatur: 

 

 -20°C bis +60°C 

Fluid temperatur: 

Solenoid core in fluid 

 -20°C bis +60°C 

 

   Solenoid core not in fluid 

 no influence 

Duty cycle: 

 

 100% 

 

 

Switching frequency 

 

Solenoid drive 

MG... 

Cycles / hour 

standard 

at + 20°C ambient 

temperature range 

at + 60°C ambient 

temperature range 

at 

opening delay 

008x - 019x 

1000 

016Ax - 019Ax 

 

20 

10 

10 

010A5x - 019A5x 

600 

10 

016A5C6x, 019A5C6x 

016A5.2C6x, 019A5.2C9 

20 

    
 
 
 

Connecting diagrm  

 

 

 

 

 

 

 
 
 
 

Supply 

 
 
 
 
 
 
 
 
 
 
 

Connecting area 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

717/1 

717/2 

 

 

Housing 

 

 

NOTE! 

The solenoid drive must be additionally grounded via an Ex-grounding 
terminal (717/2). Eighth case of DC voltage for correct polarity 1+ / 2- 

 

Summary of Contents for MG X Series

Page 1: ...om the type plate Solenoid actuators are electrotechnical components that are inoperative without the associated valve and also may not be operated for themselves alone For outdoor installations alway...

Page 2: ...nge clamping range of the cable gland must be noted and adhered to Where a flexible connecting line is used insulated wire end sleeves with plastic collars conforming to DIN 46228 part 4 are to be use...

Page 3: ...may cause damage within the installation the user must possibly provide additional protective measures which go beyond the installed varistor Dismounting of the solenoid drive ATTENTION Disconnect th...

Page 4: ...istor control TS and remove ex chamber cover 127 putting it onto a clear surface Loosen the cylinder head screw 910 1 and remove it with the lock washer 905 1 The magnet plate 500 may be removed from...

Page 5: ...5 Solenoid drive MG x MG A x List of parts Item Qty Description 103 1 Solenoid housing 105 1 Solenoid housing cover 106 1 Upper part of housing 127 1 Ex chamber cover 403 1 O ring 500 1 Solenoid plate...

Page 6: ...e housing 106 as well as Ex chamber cover 127 must be free of any defective parts or scratches The surfaces are to be greased with Kl berplex BE 31 502 grease On tightening of the cylinder head screw...

Page 7: ...21 220 100 040 09 Solenoid Drive Series MG X MG A X With protection for intended use in ex zone 1 in accordance with 2014 34 EU ATEX 95 MG x MG A x with internal control in solenoid drive Solenoid val...

Page 8: ...5 Max temperature of housing 95 C Ambient temperatur 20 C bis 60 C Fluid temperatur Solenoid core in fluid 20 C bis 60 C Solenoid core not in fluid no influence Duty cycle 100 Switching frequency Sole...

Page 9: ...Holtumsweg 13 D 47652 Weeze Tel 49 2837 9134 0 Fax 49 2837 1444 www uni geraete de info uni geraete de Seite 9 9 TM 4021 220 100 040 09 Solenoid Drive Series MG X MG A X With protection for intended u...

Reviews: