UNI-Geräte E. Mangelmann Elektrotechnische Fabrik GmbH
Holtumsweg 13, D-47652 Weeze, Tel. +49 2837/9134-0, Fax. +49 2837/1444
www.uni-geraete.de [email protected]
Seite 4/9
TM 4021
220.100.040-09
Solenoid Drive
Series MG…X, MG…-A.X
With - protection for intended use in ex- zone 1
in accordance with 2014/34/EU (ATEX 95)
A..x (pick-up coil and restraining coil) at the connection clamp of the transistor control (TS..)
and remove ex-chamber cover (127) putting it onto a clear surface.
Loosen the cylinder head screw (910/1) and remove it with the lock washer (905/1). The
magnet plate (500) may be removed from the upper part of the housing (106) by screwing two
cylinder head screws (M8 x 40 mm) into the magnet plate.
NOTE!
The dowel pins (943/1 and 943/2) are in the magnet plate (500) and
must be driven out after dismounting.
Remove the solenoid housing (103) from the upper part of the housing (106) and take out the
magnet coil (702).
ATTENTION!
Repair and overhauling of ignition cut-out proof opening is