Solenoid Drive 

 

Series MG…X, MG…-A.X 

 

With  - protection for intended use in ex- zone 1 
 in accordance with 2014/34/EU (ATEX 95) 

 

 

Special condition for safe use 

1.  Since  temperatures  higher  than  70°C  occur  at  the  cable  entry  and  higher  than  80°C  at  the  core 

junction,  this  equipment  must  be  additionally  marked  with  the  higher  temperature  (label  at  the 
cable entry). Only a heat-resistant cable may be connected. 

2.  The solenoid actuators need to be protected against the dangerous consequences of short circuits, 

earth faults and overloads. A line-side fuse appropriate to the rated current (max. 3xIB acc. to IEC 
60127-2-1)  is  to  chosen.  A  line-side  motor  circuit  breaker  -  with  short-circuit  and  thermal 
instantaneous  tripping  -  is  to  be  adjusted  for  the  rated  current.  If  the  magnet  has  very  low  rated 
currents, fusing with the lowest current value in keeping with the stated IEC standard is sufficient.  
Protective devices must be of the kind that prevents automatic reconnection under fault conditions. 
The  fusing  rated  voltage  must  match  or  exceed  the  specified  nominal  voltage  of  the  solenoid 
actuator.  The  breaking  capacity  of  the  fuse  link must match  or  exceed  the  maximum  short-circuit 
current expected at the place of installation (usually 1500 A). 

3.  When  a  silicon  (or  silicon  containing)  connection  lead  is  used  or  if  the  connecting  lead  is  not 

scratch  proof  respectively,  this  has  to  be  protected  from  mechanical  damage  (e.g.  inetrrupted 
tube system with edge protection). 

4.  A maximum permissible ripple of 20% is valid for all magnets of dc-design. 
5.  The  repair  and  overhaul  of  the  flameproof  joint  is  permitted  only  after  first  consulting  with  Uni-

Geräte. 

6.  The emergence of explosive atmospheres is to be avoided in the region of the magnetic core and 

guide tube. 

 

Electrical connection 

The  diameter  range  /  clamping  range  of  the  cable  gland  must  be  noted  and  adhered  to.  Where  a 
flexible connecting line is used, insulated wire-end sleeves with plastic collars conforming to DIN 46228 
part  4  are  to  be  used.  The  voltage  supply  at  the  solenoid  actuator  must  lie  within  the  range  -15%  to 
+10%.  The  appropriate  circuit  diagram  can  be  obtained  from  the  connection  diagrams  at  the  end  of 
these operating instructions. To guarantee an IP65 degree of protection, the magnetic housing lid must 
be  refitted  carefully  .  Versions  supplied  with  a  connecting  cable  ex  works  are  ready  for  use,  i.e.  the 
connection compartment does not need to be opened again.  

 

CE-Identification 

The  Council  of the  European  Community  passed  common  directives  for the  free  movement  of goods 
within  the  European  Community,  which  determine  the  minimum  requirements  for  safety  and  health 
protection. The CE-identification confirms, that the products correspond to the EC directives, i.e. are in 
agreement with the relevant, especially harmonized standards. 
Note concerning directive 2014/34/EU (explosion protection directive ATEX 95): 
The  solenoid  drives  (MG..Xn,  MG..A..Xn,  MG..A..C..Xn)  fulfil  the  relevant  requirements  of  directive 
2014/34/EU; therefore they have the CE-identification as per annex X of the directive. The declaration 
of conformity is included. 
Note concerning directive 2014/30/EU (EMV-Directive): 
The solenoid drives fulfil the requirements of the specification to be applied of the product families con- 
cerning the industrial sector as well as the sectors of private housing, business and trading, as well as 
of small businesses. 
On using of AC- and DC-variants the user must provide a suitable mains filter (e.g. X-capacitor 47 nF) 
at the mains entrance to attenuate the physically caused line-related turn-off current of the solenoid. 
In the sense of the EMV-directives solenoid drives with driving elements for valves are not regarded as 
independently  operable  appliances  and  are  only  processed  further  by  expert  companies,  or 
respectively  installed  into  a  machine.  They  must  not  be  started  up  until  it  was  determined  that  the 
machine, or respectively, the complete line, corresponds to the regulations of the EMV-directives. 

 

Summary of Contents for MG X Series

Page 1: ...om the type plate Solenoid actuators are electrotechnical components that are inoperative without the associated valve and also may not be operated for themselves alone For outdoor installations alway...

Page 2: ...nge clamping range of the cable gland must be noted and adhered to Where a flexible connecting line is used insulated wire end sleeves with plastic collars conforming to DIN 46228 part 4 are to be use...

Page 3: ...may cause damage within the installation the user must possibly provide additional protective measures which go beyond the installed varistor Dismounting of the solenoid drive ATTENTION Disconnect th...

Page 4: ...istor control TS and remove ex chamber cover 127 putting it onto a clear surface Loosen the cylinder head screw 910 1 and remove it with the lock washer 905 1 The magnet plate 500 may be removed from...

Page 5: ...5 Solenoid drive MG x MG A x List of parts Item Qty Description 103 1 Solenoid housing 105 1 Solenoid housing cover 106 1 Upper part of housing 127 1 Ex chamber cover 403 1 O ring 500 1 Solenoid plate...

Page 6: ...e housing 106 as well as Ex chamber cover 127 must be free of any defective parts or scratches The surfaces are to be greased with Kl berplex BE 31 502 grease On tightening of the cylinder head screw...

Page 7: ...21 220 100 040 09 Solenoid Drive Series MG X MG A X With protection for intended use in ex zone 1 in accordance with 2014 34 EU ATEX 95 MG x MG A x with internal control in solenoid drive Solenoid val...

Page 8: ...5 Max temperature of housing 95 C Ambient temperatur 20 C bis 60 C Fluid temperatur Solenoid core in fluid 20 C bis 60 C Solenoid core not in fluid no influence Duty cycle 100 Switching frequency Sole...

Page 9: ...Holtumsweg 13 D 47652 Weeze Tel 49 2837 9134 0 Fax 49 2837 1444 www uni geraete de info uni geraete de Seite 9 9 TM 4021 220 100 040 09 Solenoid Drive Series MG X MG A X With protection for intended u...

Reviews: