21
HydroPower® RO35C
Operation
5.2
Cleaning surfaces with the HydroPower RO
The HydroPower RO has two water outlets so that 2 people can work in parallel.
The water pressure is distributed over the 2 outlets and depends on the hose length or hose diameter
used.
We recommend regulating the water pressure between the 2 hoses, especially with height differences,
with a valve. For example the UNGER hose connection # 18330 incl. water switch or the UNGER
HiFloControl # TMOOV, regulate the water quantity at the water fed pole.
Note that the right water connection receives more water from the
membranes than the left.Therefore, long hoses or higher poles should be
connected to the right water output.
NOTE
The longer the hose from the water outlet to the water fed pole, the larger the
diameter of the hose should be.
5.3
Interruption of work
If you need to interrupt your work with the HydroPower RO, proceed as follows:
• The pump control switches off automatically in case of negative pressure. As soon as the pressure
rises back to working pressure, the pump starts up again automatically.
• You can therefore interrupt the water supply on the pole (e.g. with TMOOV HiFlo Control) and the pump
stops. As soon as you open the water supply again, the pump starts again.
• If the pump does not start automatically, you can start it by pressing the RESET button on the side of
the housing
• Alternatively, you can also switch off the device on the side with the main switch.
Water output of the connectors
ENGLISH