![unGer HydroPower RO35C Operating Instructions Manual Download Page 18](http://html1.mh-extra.com/html/unger/hydropower-ro35c/hydropower-ro35c_operating-instructions-manual_3680833018.webp)
T
www.ungerglobal.com
4
1
6
5
18
HydroPower® RO35C
Commissioning
4.4
Commissioning
CAUTION
Slight injuries due to pressurized containers possible.
`
The 4 filter vessels are pressurized during operation.
`
Never open a filter vessel during operation.
`
Check if the hoses and tubes are water-tight and fit properly before
commissioning the system.
`
Use protective gloves.
To start the HydroPower RO, proceed as follows:
ATTENTION:
For new or conserved units, the resin filter is removed from the unit and must be
inserted in step 14 !
1. Connect the hoses. Do not forget the concentrate hose at the back
of the RO35C.
2. Turn on the water supply
3. Connect the power cord to the power supply.
4. Turn on the main switch.
5. Wait until the system is completely filled with water. You can check
this by pressing the two yellow buttons on the front filters. As soon
as water comes out here, the tanks are filled.
6. Turn the yellow rotary switch to the upper position. The filtered pure
water is delivered to the two water outlets.
3