HydroPower® RO35C
Switching off
5.4
Switching off the HydroPower RO
To switch off the HydroPower RO after finishing the work, proceed as
follows:
1. Switch off the unit with the main switch.
2. Disconnect the power supply and the water supply.
3. Open the pressure relief valve at the rear of the system to allow water
to flow out of the tanks. Close it again when no more water flows out.
4. Remove the hoses from the front connections.
3
The HydroPower RO is switched off and can be transported.
6
Malfunctions
6.1
Procedure for accidents
Press the main switch located on the side of the HydroPower RO to turn off the system:
• In case of danger of injury,
• Risk of damage to the HydroPower RO.
In the event of an accident, take immediate action and call the local emergency number.
6.2
Procedure for malfunctions
During operation, the following faults may occur:
Water pressure too low
`
The inlet pressure from the water pipe is too low to provide the desired filter performance.
The pump switches off.
`
Check whether the inlet hose is kinked or if there is too little pressure on the water
pipe.
`
As soon as the problem is solved, the pump should restart by itself.
`
If the pump does not start by itself, press the blue RESET buttons on the side of the
housing.
Overpressure
Overpressure can occur if the water pressure from the pipe is more than 6 bar.
To check the water pressure in the pipe, proceed as follows:
`
The pressure gauge indicates the line pressure.
`
As soon as the pump is switched on, the pressure increases by 4 bar. If the inlet
pressure is too high, connect a water tap to the water inlet and regulate
the pressure down.