HydroPower® RO35C
Replacing filter cartridges
Inserting the filter cartridges
6. Insert a new filter cartridge into the HydroPower RO the right way round.
Carbon sediment combi prefilter (#1)
`
Here it does not matter how the filter is inserted.
RO Membranes (#2+#3)
`
The 2 RO-membranes have an imprint indicating the flow direction, the
arrow must point upwards.
`
The
rubber seal
must always be at the
top
DI-resin filter (#4)
`
The
sealing cap must be replaced
every time the filter is changed
`
To do this, remove the old sealing cap and place the new one on the guide
socket in the hopper. (see illustrations). Press down until it sits flat.
`
Insert the new filter the right way round (arrow down, paper filter up and
press carefully on the sealing cap. If it is the wrong way round, water
cannot flow through and backwater will occur.
7. Replace the top cap and turn it clockwise
.
`
The top cap locks with a „click“ and must stay in this position (see picture).
Do not turn it further !
8. Proceed the same for all other filter cartridges.
3
The filter cartridges are replaced
.
NOTE
The covers are marked with different shades of blue. The dark blue belongs to the
front left vessel for the carbon/sediment combi pre-filter, the medium blue to the
rear vessels for the membranes and the light blue to the front right vessel for the