Function 4:
Input of V and H - offset. An offset can be positive or negative. Since there is no "-" button
is available,
is a selection of "pos" or "neg" a switchover using the "F" key is provided.
The function under the 4 (V or H - offset) value entered is in the calculation of V or H
taken into account.
Function 5:
Input to determine the pulse output (selectable from 1 to 999 l / sec or 1-999 m3 / sec.
and the totalizer (potency 0-3 - means quantity counter
counts 0 = m3, 1 = 10m3, 2 = 100m3, 3 = 1000m3)
Note :
The pulse output is limited to a maximum of 1 pulse per second. That is, a plurality of pulses per
second are not possible. The pulse output has to be, if necessary, one or more numbers, or a
potency be selected higher. The pulse length is about 250ms.
Function 6:
Assignment of the analog outputs (current outputs). Here is the assignment of the issued
Parameters (V, H, Q) is set to the current outputs.
Function 7:
Assignment of the switching outputs. Here, the assignment of the parameter to be output
(V, H, Q) to the Switching outputs set.
Function 8:
Selection of the totalizer for the display and switching output. Possible are Totalizer and
totalizer per day. Totalizer means the constantly counter, totalizer per day (daily amount)
means a resettable counter, this accumulated the amount as long until it is reset.
Function 10:
Calibration factor for velocity (V) - software-based amplification of the
V - value 0.001-9.999
Function 11:
Calibration factor for level (H) - software-based amplification of the
H - value 0.001-9.999
Function 12:
Set date and time (This function is important for the correct time - date allocation of
stored data)
If the device is de-energized longer time, is it neccessary to control the time and date via
the function 99 to checked and corrected if necessary. It is important for data storage.
Function 13:
Language (german/english)
Function 14:
Simulation.
In the simulation, the chosen "Function 1" channel is used as a basis for calculation.
With the input of a certain filling level and a specific velocity can be a corresponding flow
are simulated.
The flow is displayed according to the calculation. The pulse output turns real
according to the calculated flow.
A jumping out from the simulation requires a new selection button "B" then "Function 14"
with followed by selection on simulation "off"!
Function 20:
Storage of measurement data - storage rate normal, adjustable 1-999 sec, 1-999 min..
Function 21:
Storage of measurement data – storage rate quick, adjustment like storage rate normal.
Function 22:
Level trigger for quick storage. Example: rain events can increase the level in channels.
From an adjustable level is to be saved faster. Level trigger is the adjustable fill height
for quick storage.
Function 40:
Select the boot loader. Is needed for firmware updates.
Function 41:
Setting the display brightness