UNAOHM
24
EP2500 (Rev. 0)
•
RESET. Pressing
RST
key the dish returns to 0° position.
7.10.4
User-Defined DiSEqC 1.1 Commands
The instrument offers the possibility of creating two user-defined DiSEqC commands as follows:
1.
In the normal operating mode press
DSQ (28)
Figure 7
appears on the display screen.
2.
Press
SELECT
.
Figure 8
appears on the display screen.
3.
UP
or
DOWN
. Positions the cursor in correspondence with one of the last two commands, on page
5 of 5, indicated as USER 1 and USER 2.
4.
EDIT
. The cursor shifts to the inside of the parenthesis.
5.
UP
or
DOWN
. Programs the first digit of the message to be transmitted.
6.
Shift to the following digit by means of the arrow key
(23)
and program it, once again by means
of the keys
UP
or
DOWN
7.
In the same way program all of the desired digits (max. eight). The last digit programmed may be
cancelled by means of
DELET
(E).
8.
Once the message has been completed press
BACK
or
DSQ
.
NOTE
:
DiSEqC messages are composed of bytes each consisting of two digits, therefore they will be
comprehensible only if composed of an even number of digits.
Figure 8
DiSEqC command selection display
DiSEqC commands
PAGE 1 OF 5
**
DOWN
UP
BACK
g
TONE BURST
DATA BURST
.
.
.
.
.
SW5 ON h LO E0103901
**
EDIT /DELET