- 17 -
4.8 Installation of the oil mist separators (Option)
An oil mist separators can be installed in order to remove oil mist from the pump. In GCD-051X,
it is an OMC
-050
type, In GCD-136X,201X, they are an OMC-200 type. Attach in the outlet
pipe of a pump by quick coupling of KF-25 (NW-25). The oil mist separators not only prevents
oil mist generation but also reduces exhaust noise.
For details, refer to the instruction manual for the oil mist separators.
4.9 Restriction on operation when the oil mist separators is installed
When using the oil mist separators, there are some restrictions on operation. When the filter is
clogged, replace it.
The internal pump pressure is limited to 0.03 MPa (gauge pressure). When the pressure
measured at the outlet side has reached 0.03 MPa (gauge pressure), replace the oil mist
separators filter.
Be sure to observe the restrictions on operation when the oil mist separators
is installed. There is a risk of explosion. When the filter is clogged, replace
it.
Warning