10
Interlink Learning Mode
1. Press the test button on another alarm three times within 2 seconds,
repeating for all alarms within ten seconds of each other.
2. This connects the alarms to the master unit.
3. Once an alarm successfully receives the master unit’s radio-interlink code
the red LED will flash for about two seconds. The alarm will then exit learning
mode automatically and return to standby operation.
Note:
When the alarm is in master mode you can press the test button at any
time to exit and return to standby operation.
Interlink Master Mode
1. Press the test button three times within two seconds on an optical smoke
alarm; if the red LED flashes once then the alarm has entered learning mode,
otherwise repeat accordingly.
2. If this alarm has not received a wireless interlink code within 2 seconds it will
go into master mode. At this point the red LED should always be on.
3. In master mode the alarm is constantly transmitting a wireless interlink code;
if there is no response to this command within 10 seconds, the alarm will exit
master mode automatically and return to standby operation.