background image

PAGE 9                                                                                                    

INSTALL GUIDE

                                                                                                                                 

Wiring Descriptions

 

AUXILIARY CONNECTOR (14 pin)

 
        Pin                      Function                            

Description

1-YELLOW

      Re-arm(-)

 - 

0.75 second pulse output when    button is 

                                               pressed and after remote start shutdown.
                                               Used for factory alarm re-arm.(menu 3)

2-RED/

             Trunk Release(-)

 - Programmable output. Hold the    button

    

WHITE 

                                       for 3 seconds, output will stay active (max 

                                                         5 seconds) or programmable (-)park light.

3-BROWN       

Dis-arm(-)

 - 0.75 second pulse when the

    

button is pressed 

                                                and before remote starter activation.
                                                 Used for factory alarm dis-arm.

4-ORANGE

     

Anti-Grind/Starter Kill(-)

 -Output active during remote start.

                                                                      Programmable Starter Kill (menu 3)

5-WHITE/        

Horn(-)

 - Output to activate factory horn. (12xx/32xx series) 

or

    

BLUE

            Siren(+)

 - 

Output to activate external siren. (22xx/42xx series) 

6-N/A
7-PURPLE     

 Door Pin(+) 

- Input to detect 12v when door is open. 

                     

8-WHITE         

Park Light(+)

 - 10amp positive output to activate park lights.

                                                     Programmable output (menu 2)

9-GREEN/       

Hood Pin(-)

 - Input to detect ground when hood is open.

   

 WHITE

                            

MUST BE CONNECTED.

10-GREEN      

Door Pin(-)

 -Input to detect (-) when door is open.

11-BLACK      

Ground(-)

 - System chassis ground input.

12-PINK          

Brake Light (+)

 - Positive brake light switch input. Used to 

                                                        detect the brake switch being applied

.

13-BLUE/        

Tach(A/C)

 - A/C Tach signal input. Used to detect engine

     WHITE

                         

speed to indicate vehicle is running.

                                                

(Coil, Injector, cam/crank position sensors)

14-BLUE         

/-)

 - Programmable Wait to Start Input. Detects 12v or

                                                negative signals.(menu 3)

Summary of Contents for 2500M SERIES

Page 1: ...an Enclosed Building Garage Carport etc The Hood Pin Safety Switch Must Always be Installed Warning CARBON MONOXIDE MAY CAUSE SERIOUS INJURY EVEN DEATH It is the sole responsibility of the user to pla...

Page 2: ...Quick Learn Tach System Reset Page 14 Programming Overview Pages 15 16 Entering Program Mode Quick View Programming Program Menus Pages 17 22 Program Menu 1 User Settings Program Menu 2 Additional Se...

Page 3: ...n Run Time 4 15 45 minutes Door locks 125s 75s 3s Double unlock Ignition lock unlock Horn or Siren output 5ms 10ms 50ms Timer Mode Star with 3 different start intervals Programmable Wait to Start or d...

Page 4: ...ections Proper Connections Remote Starters can handle loads of up to 30 amps for extended periods of time It is critical to insure that all high current connections are properly soldered and insulated...

Page 5: ...e BLUE connector on the Control Module Testing The System When the installation is complete it will be necessary to test that the system is working correctly The system s default programming will work...

Page 6: ...p Diesel Wait To Start Input or 12volt Input 30amp Dis arm Output 250ma Hood Pin Switch Input Ignition Output Park Brake Input Brake Light Switch Input Selectable Output Horn Siren Output 250ma System...

Page 7: ...nd Ignition Position 3 Status Led s Program Button The antenna MUST be connected for the system to operate The centre pin of the keyless entry harness is ONLY available with plug in devices such as th...

Page 8: ...ositions 12 14V in the ACCESSORY key position 3 RED 12volt Input 30amp Supplies 12votls for the IGNITION PARK LIGHT and SELECTABLE outputs 4 RED 12volt Input 30amp Supplies 12 volts for ACC and STARTE...

Page 9: ...3 5 WHITE Horn Output to activate factory horn 12xx 32xx series or BLUE Siren Output to activate external siren 22xx 42xx series 6 N A 7 PURPLE Door Pin Input to detect 12v when door is open 8 WHITE...

Page 10: ...t the remote starters Starter Output wire directly to the starter motor side of the clutch switch Type 2 Negative High Current This switch grounds the factory starter relay and allows the vehicle to s...

Page 11: ...lectable Output for vehicles that may require a 2nd Ignition Accessory or Start Auxiliary Connector 14pin BLACK System Ground Input Connect to Chassis Ground WHITE Park Light Output Connect to Park Li...

Page 12: ...reset the system see System Reset page 14 and repeat step 1 If the park lights do not flash in auto tach learn mode it may be necessary to connect to a different tach source It is important the ignit...

Page 13: ...press and hold the Program Button 4 The park lights will flash to confirm Quick Learn Tach Important Tach Notes Quick Learn Tach with Blue White connected only Quick Learn Tach is designed to re learn...

Page 14: ...nna The park lights will turn on and the siren or horn optional will chirp one time 3 Then press and hold the Program Button until the park lights flash and the siren or horn optional will chirp 3 tim...

Page 15: ...confirm the desired setting For example 1 flash chirp Setting 1 2 flashes chirps Setting 2 etc c Turning the ignition key to the Off position or 30 seconds of no activity will exit Program Mode This...

Page 16: ...er 5 Reservation Mode Manual Auto Reservation Menu 3 Press 1 Flash 2 Flashes 3 Flashes 1 Lock Unlock Type Type 1 Type 2 Normal 2 Gas Diesel Negative 15 second Gas Positive 3 Rearm Output Type 1 Type 2...

Page 17: ...Lock Unlock Pulses Press Release the Program Button 3 Times Setting 3 Confirmed with 3 LED flashes Press Hold the Program Button until the appropriate of park lights siren chirps then release Press Re...

Page 18: ...Program Button to proceed to the next step Setting 7 Passive Active Arming 2271M 4271M 4266M series ONLY 1 Passive Arming 1 Flash Chirp Auto Arms 30 seconds after last door is closed 2 Active Arming...

Page 19: ...Output 2 Flashes Chirps Long Loud siren Output 3 10 ms Pulse Output 3 Flashes Chirps Normal Medium siren Output Press Release the Program Button 3 Times Setting 3 confirmed 3 LED flashes Press Hold th...

Page 20: ...step Setting 3 Rearm Output 14 pin auxiliary connector pin 1 1 Type 1 1 Flash Chirp Pulse after start and with lock 2 Type 2 2 Flashes Chirps Pulse after start only 3 Factory Re arm 3 Flashes Chirps P...

Page 21: ...shes Chirps When locked 30 seconds after ignition is OFF or 2 pressed 3 GWR 3 Flashes Chirps Output during remote start only Anti grind Bypass Press Release the Program Button 6 Times Setting 6 Confir...

Page 22: ...gram Button twice LEDs will flash 2 times consecutively 4 Press and hold the Program Button NOTE The park lights will flash and the siren will chirp one time each time the park lights flash and the si...

Page 23: ...hts do not turn ON release the Program Button and turn the ignition to the OFF position wait 5sec and repeat steps 1 2 STEP 2 Press and hold the Program Button The park lights will turn ON and the sir...

Page 24: ...oof of the vehicle to the hood area To enter shock sensor programming Press and hold the and the buttons for three seconds The park lights will flash and the siren will three times To exit and save sh...

Page 25: ...irp twice and the doors will unlock opt Step 3 Turn the ignition key off and the vehicle will continue running Step 4 Exit the vehicle and close all the doors Step 5 Press and hold the button for 3 se...

Page 26: ...Door Locks More Than 250ma Positive Type Door Locks NOTE When installing relays always use a fused power source Blue Green Lock Un lock Vehicle Lock Unlock Switch To Control Relay or Actuators 87 86 8...

Page 27: ...a 30 Ground DIAGNOSTICS 13 87 86 85 87a 30 87 86 85 87a 30 Blue Green Lock Un lock To Vacuum Pump Fused 12V x Cut Ground 5 Wire Reverse Polarity Type Door Locks Aftermarket Doorlock Actuators Vacuum T...

Page 28: ...etect the tach signal 8 Flashes The system made 3 start attempts without starting To Enter Diagnostic Memory Mode Step 1 Turn the ignition ON then OFF Press and release the Program Button Step 2 The s...

Reviews: