GENERAL INFORMATION

This  equipment  is  designed  and  sold  for  commercial  use  only  by  personnel  trained  and 

experienced in its operation and is not sold for consumer use in and around the home nor for 

use directly by the general public in food service locations. 
First and foremost, each crate should be examined before signing the Bill of Lading to report 

any visible damage by the trucker in transit and to account for the proper number of crates.  

If there is apparent damage, arrangements should be made to file a claim against the carrier.  

Interstate Commerce Regulations require that the claim must be initiated by the consignee.  

Proper and secure storage facilities should be arranged for the oven(s) if necessary to protect 

it from outdoor or damp conditions at all times before installation.

 

-IMPORTANT-

When you have all the crates unloaded, open the crates and remove all plastic covers.  Inspect 

at once for concealed damage.  If anything appears to be damaged, contact the appropriate 

persons immediately to file a damage claim.  After completing this inspection, finish unpacking 

the oven.  

Be sure to remove all paper protection and packing material from the unit 

prior to heating.

 

 

CAUTION

FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE 
VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.

INSTALLATION

The ovens are equipped for the voltage indicated on the nameplate mounted on the rear of 

the control box.  They will operate on alternating current (AC) only.  A cord is provided with a 

NEMA 6-50 plug.  A matching receptacle with 50A supply must be provided.

 

 

WARNING

DO NOT CONNECT TO DIRECT CURRENT (DC).

The installation of the electric oven should conform to the:

NATIONAL  ELECTRIC  CODE  AND  ALL  LOCAL  ELECTRIC  CODES  AND 
ORDINANCES  AND  THE  LOCAL  ELECTRIC  COMPANY  RULES  AND 
REGULATIONS.

PURCHASER'S RESPONSIBILITY

It is the responsibility of the purchaser:
1.  To see that the electric services for the oven are installed on site in accordance with the 

manufacturer's specifications.

2.  To unload, uncrate, and install the oven in its proper location and in accordance with this 

installation operation manual.

3.  To see that electric services are connected properly by a qualified installer of your choice.  

All such connections must be in accordance with applicable code requirements.

4.  To arrange for inspection and operation check-out by an authorized service technician.

  

The warranty becomes effective upon verification of proper installation.

4

Summary of Contents for UM1833-208V

Page 1: ...ELECTRIC CONVEYOR OVEN MODEL UM1833 208V UM1833 240V UM1850 208V UM1850 240V Installation and Operation Instructions 2M Z6599 Rev E 2 04 2010 UM1850...

Page 2: ...information provided or conclusions reached as a result of using the speci cations By using the information provided the user assumes all risks in connection with such use MAINTENANCE AND REPAIRS Con...

Page 3: ...on 6 400 Watts 6 000 element 32 29 Amps at 208 240V NEMA 6 50 plus with six foot oil resistant cord Electrical Supply Separate 50 Amp 208 240VAC single phase 50 60 Hz service per Oven Approximate Weig...

Page 4: ...n and packing material from the unit prior to heating CAUTION FORYOURSAFETYDONOTSTOREORUSEGASOLINEOROTHERFLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE INSTALLATION The ov...

Page 5: ...IONS CONTAINED HEREIN ARE FOR THE USE OF QUALIFIED INSTALLATIONAND SERVICE PERSONNELONLY INSTALLATION OR SERVICE BY OTHER THAN QUALIFIED PERSONNEL MAY RESULT IN DAMAGE TO THE OVEN AND OR INJURY TO THE...

Page 6: ...vent airflow through the cooking tunnel Air must NOT be directed onto the oven s front or rear or to the sides of the cooking area This can cause incomplete or uneven baking and increased energy consu...

Page 7: ...is properly installed and in working order The warranty becomes effective upon verification of proper installation Unless specified otherwise conveyor travel is factory set for left to right operatio...

Page 8: ...in one minute push the power Push power switch ON To Start HEAT LIGHT General Safety Tips 1 If the oven needs to be moved for any reason the power must be disconnected from the unit before doing so 2...

Page 9: ...w for an additional 4 seconds The TEMP display shows LOC as the TIME display shows nO which indicates that the TIME TEMP parameters can be changed after reaching the STORE level yES indicates that the...

Page 10: ...n established the fine adjustments should be made by holding either the bake time or bake temperature constant then varying the other CONVEYOR SPEED Bake Time Conveyor Speed As stated previously bake...

Page 11: ...he aluminized finish of the oven interior 3 When using cleaning solutions be sure they meet local and national health standards Follow this recommended cleaning schedule for proper oven performance DA...

Page 12: ...omplete or the small handle left canbeusedtoslide nozzle and columnating plate out before removing the main body 7 The lower finger assembly can be removed complete or the nozzle can be slid off to re...

Page 13: ...ntinuous use Following are the necessary steps for removing links 1 Move the splice clips to either end of the oven for easy access 2 Unhook the splice clips using long nose pliers 3 Unhook the full l...

Page 14: ...s This warranty does not apply to the non stick properties of such materials This warranty does not apply to Special Products but to regular catalog items only Star s warranty on Special Products is s...

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ......

Page 19: ...BE TUBE 14 G9 EC0025 1 CONVEYOR FRAME UM1833 G9 EC0043 1 CONVEYOR FRAME UM1850 15 2A Z6538 1 DRIVESHAFT ASSEMBLY W SPROCKETS 17 2A Z5586 1 2 IDLER SHAFT S W SPROCKETS UM1833 UM1850 18 2B Z5709 1 BELT...

Page 20: ......

Page 21: ...ATURE X CE C 4 2E Z5683 1 VACUUM LIMIT SWITCH Contact Service if replacing 2E Z5180 5 2T Z5175 1 THERMOSTAT 120 F 6 2T Z5176 1 THERMOSTAT 140 F 7 2T Z5177 1 HIGH TEMPERATURE LIMIT THERMOSTAT 8 2E Z185...

Page 22: ......

Page 23: ...ot be available Number Per Unit Description Star Manufacturing International Inc MODEL Part Number Key Number Ultra Max Electric Conveyor Oven 8B UM1833 1850 208 240V Finger Assembly 1 G9 GC0037 1 LOW...

Page 24: ...enl vement 1 D placez les pissure attaches n importe quelle extr mit du four pour l acc s facile 2 D crochez les pissure attaches en utilisant de longues nez pinces 3 D crochez le plein lien enlever...

Page 25: ...tre complet enlev ou la petite poign e gauche peut tre utilis e pour glisser le bec et le plat columnating dehors avant d enlever le corps principal 7 Le doigt inf rieur peut tre enlev complet ou le b...

Page 26: ...t des solutions de nettoyage soyez s r qu elles r pondent des normes locales et nationales de sant Suivez ces recommandations pour nettoyer et maintenir de four CHAQUE JOUR 1 Nettoyez la bande de conv...

Page 27: ...produit br l 4 Une fois un bon cuisinier a t tabli les ajustements fins devrait tre fait en jugeant le temps de cuisinier ou la constante de la temp rature de cuisinier changeant alors l autre VITESS...

Page 28: ...la TEMP RATURE montre LOC pendant que l affichage de TEMPS montre nO ce qui indique que les param tres de TEMPS TEMPERATURE peuvent tre chang s apr satteinte du Stockez de Niveau yES indique que les...

Page 29: ...et LEVEZ les fl ches en m me temps Tenez pendant quatre secondes jusqu ce que l affichage de la TEMP RATURE aille blanc 2 Appuyez sur le bouton de ENTREZ pour commuter entre le TEMPS et la TEMP RATURE...

Page 30: ...toile afin d assurer le four est correctement install et dans l ordre d entretien La garantie devient efficace lors de la v rification de l installation appropri e ATTENTION NE TRAVAILLEZ PAS AUTOUR...

Page 31: ...peuvent changer dans tout le pays selon l endroit par la ville le comt et l tat Obtenez l information de l autorit ayant la juridiction pour d terminer les conditions pour votre installation Obtenez l...

Page 32: ...TALLATION CONTENUES CI dessus SONT POUR L USAGE DU PERSONNEL QUALIFI D INSTALLATION ET DE SERVICE SEULEMENT L INSTALLATION OU LE SERVICE PR S AUTRE QUE LE PERSONNEL QUALIFI PEUT AVOIR COMME CONS QUENC...

Page 33: ...r de enlever tout le mat riel de papier de protection et emballage partir de unit avant chauffage ATTENTION POUR VOTRE S RET NE STOCKEZ PAS OU EMPLOYEZ PAS ESSENCE OU AUTRES VAPEURS ET LIQUIDES INFLAM...

Page 34: ...tag res Profondeur 30 4 77 2 cm Hauteur 20 0 50 8 cm Un four avec des jambes 36 0 91 4 cm Deux fours avec des jambes UM1850 208V UM1850 240V Evaluer Raccordement 6 400W 6 000 l ment 32 29A 208 240V N...

Page 35: ...l entretien requis R f rez vous la liste autoris e de centre commercial quip e d unit Le service SVP de service de Star 1 800 807 9054 disponible pendant des heures de travail normales pour r pondre t...

Page 36: ...Instructions d installation et d op ration 2M Z6599 Rev E 2 04 2010 FOUR de CONVOYEUR LECTRIQUE MOD LES UM1833 208V UM1833 240V UM1850 208V UM1850 240V UM1850...