HyperSpike
®
HS-18 RAHD Operation and Maintenance Manual
Copyright © Ultra Electronics USSI Columbia City, IN 46725 USA
90207A-MAN-HS18RAHD
REV C
30
Figure 41: Edit Device Popup
– Deadzone Creation
Enter a name for the Deadz
one you wish to create in the “Name” field of the Deadzones
section. A Deadzone is defined by a range of pan and tilt coordinates.* Enter the desired
coordinates within the “Pan” and “Tilt” text fields. In the “Restrictions” dropdown box, select
the functionality you would like to restrict within the Deadzone. Restricting movement will
prevent the HS-18 RAHD from entering the Deadzone at all, while restricting audio will only
disable audio while traveling through the Deadzone.
*Note: A Deadz
one’s included angles will always be interpreted as follows:
The range of Pan angles
beginning at the “Min” angle, progressing in the clockwise
direction, and ending at the “Max” angle.
The range of Tilt angles beginning at the “Min” angle, progressing in the (+) direction,
and ending at the “Max” angle.
When a device enters a Deadzone, a warning will appear on screen. This warning includes
information such as the Deadz
one’s boundaries and restrictions.