Ultra-Aire MD33 Installation Instructions

www.InWallDehumidifier.com | (800) 533-7533

Step 10.

 Once electrical and drain hose are routed 

through the unit, set the unit into the wall. 

Step 9.

 Lift the unit and place it near the wall opening to route 

electrical wires through appropriate knock out and drain hose 

through hole. 
If access cover was not removed, insert grommet into knock out 

hole and snap into place before routing drain hose through.

It is recommended to have two people to lift the unit. Place  

one hand under the drain pan to support the unit during this step.  

  

Wall

MD33

14 1/2"

Side View

Drain Hose

and Electrical

Steps 9 - 10

DEHUMIDIFIER INSTALLATION

Step 11. 

Insert the dehumidifier into the center of the opening, 

allowing for a minimum of 1/8

"

 clearance from framing on both 

sides. Additional insulation or sound dampening material (not 

provided) may be required if the dehumidifier cabinet contacts 

the studs, especially in applications involving metal studs.
Fasten the unit to the framing by inserting four of the #10 

(wood) or #8 (sheet metal) screws into the slotted holes. 
Top and bottom blocking is not necessary for securing the  

dehumidifier. Any existing blocking, headers or framing  

should not intrude into the rough opening and be a minimum 

of 1/2

"

 away from the cabinet.

The cabinet is designed to create 1/2

"

 clearance to the back 

wall when installed inside a standard 2x6 stud space with  

1/2

"

 minimum drywall sheathing.

For alternate installations, maintain 1/2

"

 clearance to back  

of wall of dehumidifier cabinet.

11.

Before securing the unit into place, make sure it is level. Level  

or slightly forward is acceptable, but never backwards.

15 1/2

"

15

"

1˚-2˚

OK

OK

NOT 

OK

Fr

ont

Fr

ont

Fr

ont

 

CAUTION!

THE UNIT IS NOT SECURED YET.

Summary of Contents for MD33

Page 1: ...l framing The Ultra Aire MD33 provides the ultimate in comfort health and property protection TS 927 6 18 Rev E P N 4035900 Serial No Install Date Sold by HVAC Installer Please Leave Manual for Homeow...

Page 2: ...rements 7 Dehumidifier Installation 8 Maintenance 12 Air Flow 12 Controls 13 Service 15 Warranty 17 TABLE OF CONTENTS Therma Stor is committed to manufacturing quality products To maintain our standar...

Page 3: ...TRICAL AND PLUMBING CODES MUST BE ADHERED TO FOR PROPER UNIT OPERATION AND WARRANTY COMPLIANCE IMPROPER INSTALLATION MAY CAUSE PROPERTY DAMAGE OR INJURY INSTALLATION SERVICE AND MAINTENANCE MUST BE PE...

Page 4: ...DOIVENT TRE RESPECT S POUR UNE UTILISATION AD QUATE DE CETTE UNIT ET UNE VALIDIT DE LA GARANTIE UNE INSTALLATION NON CONFORME PEUT CAUSER DES DOMMAGES MAT RIELS OU DES BLESSURES TOUTE INSTALLATION TO...

Page 5: ...ted behind tamper proof cover Air Filter 1 2 Washable mounted behind diffuser Dehumidistat Digital tamper proof float switch input Cabinet Galvanized Steel Decibels 46 dBA Drain Connection 3 4 O D Dra...

Page 6: ...ing members or unwanted noise may result Unit is designed to be suspended by side mounting flanges only Drain hose must be routed with downward slope from unit drain connection to appropriate location...

Page 7: ...z AC only 15 amp fused and grounded electrical supply A visible circuit breaker or disconnect switch near the unit is required for maintenance and service A dedicated circuit is recommended Use of a U...

Page 8: ...ER POWER BEFORE BEGINNING INSTALLATION 1 2 Electrical Box Shipping Bracket AVERTISSEMENT FERMEZ LE DISJONCTEUR ALIMENTATION AVANT DE COMMENCER L INSTALLATION Items Included in Box Ultra Aire MD33 Dehu...

Page 9: ...p 3 There are three electrical knock outs one on the back and two on the bottom of the unit Remove appropriate knock out and install non metallic cable clamp with clamp screws inside of unit oriented...

Page 10: ...ng on both sides Additional insulation or sound dampening material not provided may be required if the dehumidifier cabinet contacts the studs especially in applications involving metal studs Fasten t...

Page 11: ...e of the electrical wires are pinched Step 15 Turn breaker power back on Step 16 Set the digital controller to desired RH See Controls Section on page 13 Step 17 Install diffuser cover by aligning the...

Page 12: ...ORD IS DAMAGED IT MUST BE REPLACED BY THE MANUFACTURER ITS SERVICE AGENT OR SIMILARLY QUALIFIED PERSONS IN ORDER TO AVOID A HAZARD AVERTISSEMENT ASSUREZ VOUS QUE L UNIT EST FERM E OU D BRANCH E OU QUE...

Page 13: ...will show 00 for a couple of seconds and then it will display the RH level of the room and the dehumidifier blower will turn on to start sampling the air for one minute Indicator LED located above di...

Page 14: ...after an hour Evaporator Temperature Mode To enter evaporator temperature mode press and hold both arrow buttons for 5 seconds and the LED will change to Blue The display will flash at twice the rate...

Page 15: ...TO PERFORM SOME TESTS THESE TESTS SHOULD BE PERFORMED BY A QUALIFIED SERVICE PERSON MISE EN GARDE LES TRAVAUX DE D PANNAGE NE DEVRAIENT TRE EFFECTU S QUE PAR UN TECHNICIEN CVCA QUALIFI AVERTISSEMENT...

Page 16: ...ning 1 Wiring or connectors loose 2 Blower relay failure 3 Blower capacitor failure 4 Blower failure Check wiring and connectors for damage or loose connections Check power to blower circuit replace p...

Page 17: ...y costs related to changes to a Product or Component that may be required by any codes laws or regulations that may become effective after initial purchase of the Product by Customer Customer Responsi...

Page 18: ...18 Ultra Aire MD33 Installation Instructions www InWallDehumidifier com 800 533 7533...

Page 19: ...19 www InWallDehumidifier com 800 533 7533 Ultra Aire MD33 Installation Instructions...

Page 20: ......

Reviews: