![ULTIMATE SPEED 354271 2010 Translation Of The Original Instructions Download Page 22](http://html1.mh-extra.com/html/ultimate-speed/354271-2010/354271-2010_translation-of-the-original-instructions_3416425022.webp)
22
GB/IE/NI/CY/MT
then programs 2-3-4 cannot be selected. The charging pro-
cess continues automatically. Depending on the program
selected, the charging characteristics for voltage, time
and temperature are monitored. With diagnosis program,
revival mode and trickle charging.
Program
max. (V)
max. (A)
1
7.3 V
0.8 A
2
14.4 V
0.8 A
3
14.4 V
5.0 A
4
14.7 V
5.0 A
Program 1
, "6 V", (7.3 V / 0.8 A)
To charge 6 V batteries with a capacity less than 14 Ah.
Press the program selector button
11
to select Program 1.
The symbol
7
is shown in the LC display. During the
charging process, the charging display
8
flashes and
shows how far the charging process has progressed
(1 – 4 bars). When the battery is fully charged, the status
display
9
shows 4 bars. The flashing stops and the device
switches to trickle charging automatically.
Program 2
, "12 V", (14.4 V / 0.8 A)
To charge 12 V batteries with a capacity less than 14 Ah.
Press the program selector button
11
to select Program 2.
The symbol
4
is shown in the LC display. During the
charging process, the charging display
8
flashes and
shows how far the charging process has progressed
(1 – 4 bars). When the battery is fully charged, the status
display
9
shows 4 bars. The flashing stops and the device
switches to trickle charging automatically.