22
GB
selected, the charging characteristics for voltage, time
and temperature are monitored. With diagnosis program,
revival mode and trickle charging.
Program
max. (V)
max. (A)
1
7.3 V
0.8 A
2
14.4 V
0.8 A
3
14.4 V
5.0 A
4
14.7 V
5.0 A
Program 1
, "6 V", (7.3 V / 0.8 A)
To charge 6 V batteries with a capacity less than 14 Ah.
Press the program selector button
11
to select Program 1.
The symbol
7
is shown in the LC display. During the
charging process, the charging display
8
flashes and
shows how far the charging process has progressed
(1 – 4 bars). When the battery is fully charged, the status
display
9
shows 4 bars. The flashing stops and the device
switches to trickle charging automatically.
Program 2
, "12 V", (14.4 V / 0.8 A)
To charge 12 V batteries with a capacity less than 14 Ah.
Press the program selector button
11
to select Program 2.
The symbol
4
is shown in the LC display. During the
charging process, the charging display
8
flashes and
shows how far the charging process has progressed
(1 – 4 bars). When the battery is fully charged, the status
display
9
shows 4 bars. The flashing stops and the device
switches to trickle charging automatically.
Using the device