background image

- 6 - 

Strobe lamp:

 

The  strobe  lamp is  attached  to  the  mount  with  2  screw  lugs  on  the  base  board.    The 
plug  from  the  strobe  lamp  is  plugged  into  connector  4  (Blitz  (Strobe))  on  any  main 
lighting stick.  

 

 

Chassis, white 

 Lightning power, yellow 

 

Sound module:

 

Plug  the  small  four  way  SUSI  connector  from  the  Sound  module  into  connector  3  
(SUSI) of any Main lighting stick.  Attach the Sound module with the enclosed adhesive 
pad close to the SUSI socket. Attach the loudspeaker as required, close to the Sound 
module.  

5.4 Connecting LED Luminaires 

For precise illumination (e.g. Spot) a dimmable 12V LED Luminaire can be connected 
to  the  2-way  screw  terminal.    The  maximum  load  capacity  of  the  luminaire  is  2  W.  
Take  care  on  the  correct  polarity.  In  the  diagram  of  the  main  lighting stick  (see  Chap 
5.1) the terminal is marked with "+" and "-". 

5.5 Connecting LocoNet for Digital operation 

In order to trigger the light or weather events with solenoid addresses, for example, or 
from  the  IntelliLight  LED  to  switch  the  house  lights  in  synch  with  the  time  of  day, 
connect  the  LocoNet  socket  from  the  control  module  with  the  LocoNet  of  your  digital 
center  (Intellibox,  DAISY  II  DCC  Digitalset,  SC7,  Märklin  6021  with  6021-Infrared  & 
LocoNet-Adapter,  TwinCenter,  Piko  Power  Box).    Use  the  60  cm  LocoNet  cable  from 
the Starter set. 

5.6 Connecting the IntelliLight 28 000 

If an IntelliLight 28 000 already exists and is to be extended with an IntelliLight LED the 
main  lighting  stick  from  IntelliLight  LED  connector  5  is  connected  with  the  data  line 
from  the  IntelliLight  28  000  as  shown  in  the  sketch.    For  that  the  4-way  connector 
socket on the base unit 28 000 or an expansion unit 28 010 or 28 020 can be used.  

For this connection you must make an appropriate cable from a LocoNet cable.  Cut  a 
plug off a LocoNet cable and approximately 5cm  of the outer insulation.  Now connect 
the wires as follows, (e.g. soldering or terminal clips) wires 2 and 5 together. After that 
3  and  4.    The  resulting  double  line  2  &  5  is  screwed  to  terminal  2  (GND)  of  the 
connector  on  the  IntelliLight  Base  or  Expansion  module.    Double  line  3  &  4  is  then 
connected  to  terminal  3  (LN)  of  the  connector.   Wires  1  and  6  of  this  LocoNet  cable  
remain insulated and unused.  

Summary of Contents for IntelliLight LED

Page 1: ...1 Manual...

Page 2: ...cting the IntelliLight 28 000 6 6 Operation 7 6 2 Operating using Key switches analog 7 6 2 Operation via Solenoid addresses digital 8 7 Synchronization with a LocoNet Clock 8 8 1 Calling up a Control...

Page 3: ...ording to one s own wish The system can be used with analog and digital layouts The lighting system is powered with a normal Model railway transformer 2 The Components IntelliLight LED Start Set Part...

Page 4: ...hould be attached at 45 angle approx at a min distance of 80cm above the layout surface The lighting sticks should be fitted to the front edge of the layout to light up the scene It has proven useful...

Page 5: ...ble 230V power outlet 5 2 Connecting the Control Module Both the IL Net and the LocoNet sockets are on the back of the unit Pin allocation on the screw terminal connector for analogue operation LED Di...

Page 6: ...ghts in synch with the time of day connect the LocoNet socket from the control module with the LocoNet of your digital center Intellibox DAISY II DCC Digitalset SC7 M rklin 6021 with 6021 Infrared Loc...

Page 7: ...r this all white Power LEDs and also the LED Luminaire output are switched to maximum brightness As well the system clock is switched on so that this state is not independently changed 6 2 Operating u...

Page 8: ...ng time above 10000 The lighting system then starts with the programmed time and afterwards synchronizes to the system time via the LocoNet If LNCV 9 is set to value 10000 the light system starts the...

Page 9: ...coNet Programming button Press the Part number button and enter the part number of the IntelliLight LED control module here 28200 and press the key Press the Module Number button enter the module addr...

Page 10: ...ion variables CV Contrary to locomotive decoders they are not programmed via the rails but via the LocoNet and are therefore called LocoNet CV s LNCV s After calling up the IntelliLight LED module see...

Page 11: ...Factory Default 0 Module address 1 65534 1 1 Solenoid address for sunrise green and sunset red 1 2000 192 2 Solenoid address for Random event 1 red and 2 green 1 2000 193 3 Solenoid address for Rando...

Page 12: ...r Pack 15 V 1 9 A 1 9 m 2x Connecting cables 2 15 m 11 2 IntelliLight LED Main Lighting Stick 28 220 1x Main Lighting stick 1x Power Pack 15 V 1 9 A 1 9 m 1x Connecting cable 2 15 m 11 3 IntelliLight...