4. Installation of the Lighting System  

Safety Notice: 

Never look directly into the switched on LEDs.  Because of their intense 

brightness they may damage your eyes. 

Safety Notice: 

Do not touch the switched on LEDs.  Because of their high temperature 

there is a risk of injury.  

4.1 Light requirement and Positioning 

  

NOTE:  Both  the  illumination  requirement  and  positioning  of  the  lighting  sticks  greatly 
depend on the design of the layout and its presentation.  

For  optimal  lighting  of  a  layout  of  a  depth  of  up  to 
1.5m per running metre, one lighting unit is needed.  
Therefore a layout with an edge length of 1m can be 
illuminated  with  an  IntelliLight  LED  Starter  set  (a 
main lighting stick, 2 white lighting sticks). In order to 
arrange  the  lighting  effect  correctly  with  sunrise 
(morning  red)  and  sunset  (evening  red),  as  well  as 
the night effect, two white and one coloured unit are 
required.   

Depending  on  desired  light  intensity,  the  lighting

 

sticks   should be attached at 45° angle (approx) at 
a  min.  distance  of  80cm  above  the  layout  surface. 
The lighting sticks   should be fitted to the 

front

 edge of the layout to light up the scene.  

It has proven useful to fasten the lighting sticks  to a common base board.  This board 
is then hung at 

an appropriate height from the room ceilin

g with chains.  The length of 

the chains can be adjusted to provide the desired lighting effect on the layout surface.  

4.2 Mounting the Lighting Sticks  

Each lighting stick has two 3.3mm mounting holes for screwing  the lighting sticks to a 
suitable base (e.g. wood strip). 

Mount the main lighting stick.  

If  you  use  additional  white  lighting sticks,  insert  the  3-way  plug  from  one  of  the  white 
lighting  sticks  into  the  3-way  socket  of  the  main  lighting  stick.    Then  screw  the  white 
lighting stick to the base. 

Up  to  4  white  lighting  sticks  can  be  supplied  from  one  main  lighting  stick.    The  white 
lighting sticks can be attached either to the right or the left of the main lighting sticks.  

If  needed,  an  additional  main  lighting  stick  can  be  placed  at  any  location  and  white 
lighting sticks can be connected to that as required. 

 

Summary of Contents for IntelliLight LED

Page 1: ...1 Manual...

Page 2: ...cting the IntelliLight 28 000 6 6 Operation 7 6 2 Operating using Key switches analog 7 6 2 Operation via Solenoid addresses digital 8 7 Synchronization with a LocoNet Clock 8 8 1 Calling up a Control...

Page 3: ...ording to one s own wish The system can be used with analog and digital layouts The lighting system is powered with a normal Model railway transformer 2 The Components IntelliLight LED Start Set Part...

Page 4: ...hould be attached at 45 angle approx at a min distance of 80cm above the layout surface The lighting sticks should be fitted to the front edge of the layout to light up the scene It has proven useful...

Page 5: ...ble 230V power outlet 5 2 Connecting the Control Module Both the IL Net and the LocoNet sockets are on the back of the unit Pin allocation on the screw terminal connector for analogue operation LED Di...

Page 6: ...ghts in synch with the time of day connect the LocoNet socket from the control module with the LocoNet of your digital center Intellibox DAISY II DCC Digitalset SC7 M rklin 6021 with 6021 Infrared Loc...

Page 7: ...r this all white Power LEDs and also the LED Luminaire output are switched to maximum brightness As well the system clock is switched on so that this state is not independently changed 6 2 Operating u...

Page 8: ...ng time above 10000 The lighting system then starts with the programmed time and afterwards synchronizes to the system time via the LocoNet If LNCV 9 is set to value 10000 the light system starts the...

Page 9: ...coNet Programming button Press the Part number button and enter the part number of the IntelliLight LED control module here 28200 and press the key Press the Module Number button enter the module addr...

Page 10: ...ion variables CV Contrary to locomotive decoders they are not programmed via the rails but via the LocoNet and are therefore called LocoNet CV s LNCV s After calling up the IntelliLight LED module see...

Page 11: ...Factory Default 0 Module address 1 65534 1 1 Solenoid address for sunrise green and sunset red 1 2000 192 2 Solenoid address for Random event 1 red and 2 green 1 2000 193 3 Solenoid address for Rando...

Page 12: ...r Pack 15 V 1 9 A 1 9 m 2x Connecting cables 2 15 m 11 2 IntelliLight LED Main Lighting Stick 28 220 1x Main Lighting stick 1x Power Pack 15 V 1 9 A 1 9 m 1x Connecting cable 2 15 m 11 3 IntelliLight...