background image

- 3 -  

1. Description  

IntelliLight  LED  gives  you  realistic  lighting  for  your  model  railway  layout.  IntelliLight 
LED illuminates your layout depending on the time of day and weather.  

When  you  switch  the  lighting  system  on  it  starts  at  dawn.    The  sun  rises  after  a 
magnificent morning red.  If the sun sets again after an eventful day the moon bathes 
the entire layout in a mysterious silvery light.  

According to the conditions the weather is radiantly beautiful or gloomy.  Now and then 
it rains or a thunderstorm passes through and lightning flashes and it thunders. 

The routine of the day, with an adjustable time, is started when the layout is switched 
on.    The  kind  of  the  lighting  depends  on  the  time  and  cloudy  appearance. 
Thunderstorms and rain appear randomly or by the push of a button.  

Depending  on  programming

,

  the  day  passes  in  24  hours  or  up  to  20  times  faster,  in 

approximately  1¼  hours.  The  lighting  can  be  switched  manually  or  time  controlled 
automatically.

  

All  pre-programmed  time  tables  can  be  changed  in  duration  and  intensity  by  LNCV 
programming according to one’s own 

wish

.  The  system  can  be used  with  analog  and 

digital  layouts.    The  lighting  system  is  powered  with  a  normal  Model  railway 
transformer.  

2. The Components 

IntelliLight LED Start Set Part No. 28 200  

The Starter set consists of a Control Module 28 200, a power plug pack, a main lighting 
stick,  two  white  lighting  sticks  and  connecting  cables.    The  overall  length  of  the 
connected lighting sticks is 1050 mm. 

Main lighting stick Part No. 28 220  

with four white, two red and a blue power LED and includes the power  plug pack and 
connecting cable for connecting to the IntelliLight-Net.  With sockets to connect further 
white lighting sticks.  Length: 350 mm 

White lighting stick Part No. 28 210  

with four white power LEDs. Length: 350 mm 

Expansion unit 

– Lightning & Sound Part No. 28 230  

with a strobe lamp and an IntelliSound 4 Module "Rain and Thunder" with a connected 
8 Ohm, 3 W Loudspeaker.  

3. Technical Data 

Power load of the Main lighting stick 28 220 

6 VA 

Power load of the white lighting stick Part No. 28 210 

5 VA 

Power plug pack  

15 V, 1.9 A, 1.9 m 

Dimensions of the Control Module 

105 x 58 x 35 mm 

Dimensions of  Main lighting stick 

350 x 16 x 17 mm 

Dimensions of white lighting stick  

350 x 8 x 4 mm 

Maximum surface temperature of the Power LEDs 

90° C 

Summary of Contents for IntelliLight LED

Page 1: ...1 Manual...

Page 2: ...cting the IntelliLight 28 000 6 6 Operation 7 6 2 Operating using Key switches analog 7 6 2 Operation via Solenoid addresses digital 8 7 Synchronization with a LocoNet Clock 8 8 1 Calling up a Control...

Page 3: ...ording to one s own wish The system can be used with analog and digital layouts The lighting system is powered with a normal Model railway transformer 2 The Components IntelliLight LED Start Set Part...

Page 4: ...hould be attached at 45 angle approx at a min distance of 80cm above the layout surface The lighting sticks should be fitted to the front edge of the layout to light up the scene It has proven useful...

Page 5: ...ble 230V power outlet 5 2 Connecting the Control Module Both the IL Net and the LocoNet sockets are on the back of the unit Pin allocation on the screw terminal connector for analogue operation LED Di...

Page 6: ...ghts in synch with the time of day connect the LocoNet socket from the control module with the LocoNet of your digital center Intellibox DAISY II DCC Digitalset SC7 M rklin 6021 with 6021 Infrared Loc...

Page 7: ...r this all white Power LEDs and also the LED Luminaire output are switched to maximum brightness As well the system clock is switched on so that this state is not independently changed 6 2 Operating u...

Page 8: ...ng time above 10000 The lighting system then starts with the programmed time and afterwards synchronizes to the system time via the LocoNet If LNCV 9 is set to value 10000 the light system starts the...

Page 9: ...coNet Programming button Press the Part number button and enter the part number of the IntelliLight LED control module here 28200 and press the key Press the Module Number button enter the module addr...

Page 10: ...ion variables CV Contrary to locomotive decoders they are not programmed via the rails but via the LocoNet and are therefore called LocoNet CV s LNCV s After calling up the IntelliLight LED module see...

Page 11: ...Factory Default 0 Module address 1 65534 1 1 Solenoid address for sunrise green and sunset red 1 2000 192 2 Solenoid address for Random event 1 red and 2 green 1 2000 193 3 Solenoid address for Rando...

Page 12: ...r Pack 15 V 1 9 A 1 9 m 2x Connecting cables 2 15 m 11 2 IntelliLight LED Main Lighting Stick 28 220 1x Main Lighting stick 1x Power Pack 15 V 1 9 A 1 9 m 1x Connecting cable 2 15 m 11 3 IntelliLight...

Reviews: