VEGA USER GUIDE
6
INSTALLATION
This is external current source dimming - the light source dimming input requires an
external 0-10V source.
There are three connections required - the fibre port, the mains supply cable and the 0-10V
control cable. The fibre port should be connected first. connect and secure the fibre optic
connector into the collar and secure using the M5 locking screw.
connect the PSU to the Dc input jack socket on the light source, and connect the IEc cable to
the PSU. Plug the mains plug into the electrical supply socket. Switch on power the led
indicator will illuminate and the light source is ready for use. If no light is produced consult the
TROUBLESHOOTINg section of this user guide.
THE LIgHT SOURcE WILL NOT ILLUMINATE UNLESS DIP SWITcH 10 IS ON AND A 0-10V
SIgNAL IS PRESENT.
connect up the 0-10V control cable to the mini XLR sockets on the rear of the light source. The
recommended plug for these sockets is the Multicomp SVP556-TA. The pin out details for these
plugs are shown below. Either socket may be used as 0-10V IN or 0-10V OUT
CONNECTION
-
VEGA
0-10
V MODELS ONLY
Note:
UFO can supply converters for these light sources to allow them to be interfaced to
standard 3 pin XLR connectors or RJ45 connectors.
Summary of Contents for Vega SLP-2700M
Page 15: ...15 UFO LIGHTING NOTES...