ALWAYS
carry out
ALL
wiring connections and set up stages prior to connecting power to the
driver.
NO
DIMMING
OPERATION
For no dimming operation, all of the manual and remote controls are disabled.
EITHER
DIP SWITCH 1-9 OFF
DIP SWITCH 10 ON
REMOVE CURRENT SINK LINKS (G)
OR
DIP SWITCH 1-10 OFF
INSERT CURRENT SINK LINKS (G)
MANUAL
DIMMING
OPERATION
(
CURRENT
SINK
)
For manual dimming using an electronic potentiometer, the current sink screw terminal link must
first be removed – and a potentiometer connected, in its place. Only compatible electronic
potentiometers recommended by UFO are to be used.
DIP SWITCH 1-9 OFF
DIP SWITCH 10 ON
REMOVE CURRENT SINK LINK (G)
0-10
V
DIMMING
-
CURRENT
SOURCE
0-10V dimming (current source) requires an external varying 0 to 10V DC control voltage. The
control voltage will dim both LED outputs simultaneously. See 0-10V value table on following
pages.
DIP SWITCH 1-9 OFF
DIP SWITCH 10 ON
INSERT CURRENT SINK LINK (G)
DMX
DIMMING
AND
CONTROL
NOTES
:
The CC9 driver occupies two DMX channels – see DMX Channel Table on page 8.
For guidance on DMX address switch settings see DMX Address Table on page 8.
DIP SWITCH 10 OFF
DIP SWITCH 1-9 TO DMX ADDRESS VALUE
INSERT CURRENT SINK LINK (G)
CONNECT ELECTRONIC POT (G)
CONNECT 0-10V INPUT +VE & -VE TO TERMINALS (F)
DRIVER
SETUP
UNIDRIVE
CC
9
USER
GUIDE
6
Summary of Contents for Unidrive CC9
Page 14: ...NOTES UNIDRIVE CC9 USER GUIDE 14...
Page 15: ...NOTES 15 UFO LIGHTING...