7
UFO LIGHTING
INSTALLATION
CONNECTION
-
FOR
0-10
V OPERATION
There are 3 connections required – the fibre port, the mains supply cable and the 0-10V cable.
The fibre port should be connected first. Connect and secure the fibre optic connector into the
aluminium collar and secure using the M5 locking screw.
Connect the PSU/driver to the DC input jack socket on the Luminaire. Plug the mains plug into
the electrical supply socket. Switch on power the led indicator will illuminate and the light
source is ready for use. If no light is produced consult the TROUBLESHOOTING section.
Connect the 0-10V RJ45 as detailed below using CAT5 cable.
Note
: for emergency light functionality, the mains supply for the light source must be
maintained so that failure of the mains supply to the 0-10V controller will result in the light
source lighting at maximum output.
0-10V RJ45 Connections:
-VE RJ45 Brown/White (Pin 7)
+VE RJ45 Blue/White (Pin 5)
POWER SUPPLY REQUIREMENTS
The LED light source is powered from a 24V DC PSU/Constant Voltage SELV LED driver.
The driver caters for UK/European/other mains supplies using the relevant power cord
supplied.