ADDITIONAL
PROCEDURES
FOR
DECORATIVE
MANUAL
MOTOR
MODELS
Note:
Please complete relevant troubleshooting procedures before returning the unit to us for
further investigation.
ADDITIONAL
PROCEDURES
FOR
DECORATIVE
DMX
MODELS
ADDITIONAL
PROCEDURES
FOR
DECORATIVE
0-10
V
MODELS
Problem
Possible Cause(s)
Remedy
Decora
ti
ve
wheel not
turning
Motor control at minimum
Adjust motor control at rear
Dip switch no 10 not switched
on
Remove cover and switch dip
switch 10 to on
Driver circuit or motor failure
Replace illuminator
Problem
Possible Cause(s)
Remedy
Not responding
to DMX control
Dip switch no 10 is switched on
Remove cover and set dip switch 10 to
o
ff
DMX address not correctly set
Remove cover and set correct address
No DMX signal from controller
Check DMX controller for correct se
tti
ng
Wiring fault on DMX cables
Check cables and repair as required
Driver circuit failure
Replace Light Source
Problem
Possible Cause(s)
Remedy
No 0
10V signal
present
Dip switch no 10 is switched
o
ff
Remove cover and switch dip
switch no 10 to on
No 0
10v signal at illuminator
due to cable or controller fault
Check input to illuminator using
a DMM set to correct range
rec
ti
fy cable / controller fault
TROUBLESHOOTING