ATTACH

 

THE

 

ILLUMINATOR

 

TO

 

ITS

 

MOUNTING

 

PLATE

Fit the metal mounting plate to the base of the illuminator before making electrical 
connections. 
 
Remove the mounting plate and the four M3 10mm screws from the box. Invert the illuminator 
and remove the four screws securing the rubber feet. 
 
Leaving the rubber feet in place, align the plate against the feet and secure the plate to the illu-
minator with the four M3 10mm screws using an M3 pozidrive screwdriver. 
 
Do not overtighten. The illuminator can now be fixed securely to the mounting surface.

The illuminator is powered from a 24V DC PSU/Constant Voltage SELV LED driver. 
 
The driver caters for UK/European/other mains supplies using the relevant power cord 
supplied.

POWER

 

SUPPLY

 

REQUIREMENTS

There are 2 connections required – the fiber port and the mains supply cable. The fiber port 
should be connected first. Connect and secure the fiber optic connector into the collar and 
secure using the M5 locking screw. 
 
Connect the PSU to the DC input jack socket on the illuminator, and connect the IEC plug to the 
PSU. Plug the mains plug into the electrical supply socket. Switch on power the led Indicator 
will illuminate and the illuminator is ready for use. If no light is produced consult the 
TROUBLESHOOTING section of this user guide.

CONNECTION

 - 

LUNA

 

CM

MCM

TM

 

AND

 

MTM

 

MODELS

 

ONLY

LUNA

 

DMX

 

/ 0-10

V

LUNA

 

MCM

 

/

 

MTM

LUNA

 

CM

 

/

 

TM

INSTALLATION

3

UFO

 

LIGHTING

Summary of Contents for Luna CM

Page 1: ...PRODUCT USER GUIDE Luna Decorative Illuminator PLEASE READ THIS USER GUIDE BEFORE INSTALLING OPERATING OR PERFORMING MAINTENANCE ON THE ILLUMINATOR UNIT E357731 Rev C1...

Page 2: ...ny flammable surface Clearance Ventilation It is imperative that a gap of 200mm is left around the unit This is to allow air to circulate and prevent overheating The location must have free ventilatio...

Page 3: ...Voltage SELV LED driver The driver caters for UK European other mains supplies using the relevant power cord supplied POWER SUPPLY REQUIREMENTS There are 2 connections required the fiber port and the...

Page 4: ...If no light is produced consult the TROUBLESHOOTING section of this user guide Connect the DMX control cables to the Mini XLR sockets on the rear of the illuminator The recommended plug for these soc...

Page 5: ...supply socket Switch on power the led Indicator will illuminate and the illuminator is ready for use If no light is produced consult the TROUBLESHOOTING section of this user guide THE LIGHT SOURCE WIL...

Page 6: ...speed of the decorative motor is fixed but controlled by a wire link between 10V and SPD screw terminals on the PCB see image on following page With the link in place the speed is fixed at 3 75 rpm W...

Page 7: ...socket is used SETTING THE DMX ADDRESS Switch 10 must be switched off for DMX operation Set the DMX address using switches 1 9 DMX B Start Ch Dip Switches On DMX B Start Ch Dip Switches On 1 1 11 1 2...

Page 8: ...blue 2 Color wheel snap 60 129 75 Color 5 magenta 2 Color wheel snap 60 129 85 Color 4 orange 2 Color wheel snap 60 129 95 Color 3 green 2 Color wheel snap 60 129 105 Color 2 yellow 2 Color wheel sna...

Page 9: ...nal DIP switch 10 is ON the wheel will find its reference point then rotate continuously counter clockwise at 7 5 rpm If internal DIP switch 10 is then switched OFF without powering down the wheel wil...

Page 10: ...heel 0 8V Color 3 green Color wheel 1 2V Color 4 orange Color wheel 1 6V Color 5 magenta Color wheel 2V Color 6 blue Color wheel 2 3V Color 1 white Color wheel 2 6V Color 6 blue Color wheel 3V Color 5...

Page 11: ...Note A record of all maintenance MUST be kept in the table above indicating what maintenance was undertaken and when This MUST be dated for warranty purposes Date Maintenance Undertaken MAINTENANCE 1...

Page 12: ...ad no light output and LED power indicator on PSU is illumi nated but LED indicator on Illu minator not illuminated PSU failed Replace PSU Problem Possible Cause s Remedy Unit is dead no light output...

Page 13: ...inator Problem Possible Cause s Remedy Not responding to DMX control Dip switch no 10 is switched on Remove cover and set dip switch 10 to o DMX address not correctly set Remove cover and set correct...

Page 14: ...C Max Ambient Temperature 45 C Fan 60mm crossflow 12V Led Type White light DMX specific models only User addressable 0 10V specific models only 0 10V DC receiving LED Life 50 000 hours typical CRI 30...

Page 15: ...NOTES 7 UFO LIGHTING...

Page 16: ...dsfactory AG Gutenbergstra e 1 85737 Munchen Deutschland 49 0 9491 955880 www ufo licht de Universal Fiber Optics USA LLC 1749 Northgate Blvd Sarasota FL34234 USA 941 343 8115 www fiberopticlighting c...

Reviews: