background image

MODELS

 

COVERED

 

BY

 

THIS

 

USER

 

GUIDE

UFO Luna CM / UFO Luna TM 
UFO Luna MCM / UFO Luna MTM 
UFO Luna CDMX / UFO Luna TDMX 
UFO Luna C 0-10V / UFO Luna T 0-10V 

IMPORTANT

This product must be installed in accordance with the applicable installation code, by a person 
familiar with the construction and operation of the product, and the hazards involved. 
 
These illuminators are not mains dimmable. 
 
The LED array in this illuminator is not replaceable. When it reaches end of life the whole unit 
must be replaced.  
 

Type Y Attachment: 

If the external flexible cable or cord of this luminaire or associated 

PSU/driver is damaged. It shall be exclusively replaced by the manufacturer or his service agent 
or a similar qualified person to avoid a hazard. 
 

Location: 

Do not locate this illuminator closer than 200mm from any flammable surface. 

 

Clearance / Ventilation: 

It is imperative that a gap of 200mm is left around the unit. This is to 

allow air to circulate and prevent overheating. The location must have free ventilation and must 
not have an ambient temperature higher than that specified for the luminaire. 
 

Mounting: 

 This is a fixed luminaire. See mounting plate instruction on Page 3 for 

fixing to surface. 
 

Warning: 

Never look directly into the luminaire LED illuminator. 

 

Warning: 

The luminaire should be positioned so that prolonged staring into the 

luminaire at a distance closer than 0.33m is not expected

Thank you for purchasing this UFO illuminator. 
 
To ensure that the illuminator is set up optimally and gives a long service life, please read this 
user guide before installing, operating or performing any maintenance on the unit. 
 
Please keep this user guide for future reference. 
 
This illuminator is suitable for indoor use only unless it is situated in a weatherproof enclosure.

INTRODUCTION

LUNA

 

USER

 

GUIDE

2

Summary of Contents for Luna CM

Page 1: ...PRODUCT USER GUIDE Luna Decorative Illuminator PLEASE READ THIS USER GUIDE BEFORE INSTALLING OPERATING OR PERFORMING MAINTENANCE ON THE ILLUMINATOR UNIT E357731 Rev C1...

Page 2: ...ny flammable surface Clearance Ventilation It is imperative that a gap of 200mm is left around the unit This is to allow air to circulate and prevent overheating The location must have free ventilatio...

Page 3: ...Voltage SELV LED driver The driver caters for UK European other mains supplies using the relevant power cord supplied POWER SUPPLY REQUIREMENTS There are 2 connections required the fiber port and the...

Page 4: ...If no light is produced consult the TROUBLESHOOTING section of this user guide Connect the DMX control cables to the Mini XLR sockets on the rear of the illuminator The recommended plug for these soc...

Page 5: ...supply socket Switch on power the led Indicator will illuminate and the illuminator is ready for use If no light is produced consult the TROUBLESHOOTING section of this user guide THE LIGHT SOURCE WIL...

Page 6: ...speed of the decorative motor is fixed but controlled by a wire link between 10V and SPD screw terminals on the PCB see image on following page With the link in place the speed is fixed at 3 75 rpm W...

Page 7: ...socket is used SETTING THE DMX ADDRESS Switch 10 must be switched off for DMX operation Set the DMX address using switches 1 9 DMX B Start Ch Dip Switches On DMX B Start Ch Dip Switches On 1 1 11 1 2...

Page 8: ...blue 2 Color wheel snap 60 129 75 Color 5 magenta 2 Color wheel snap 60 129 85 Color 4 orange 2 Color wheel snap 60 129 95 Color 3 green 2 Color wheel snap 60 129 105 Color 2 yellow 2 Color wheel sna...

Page 9: ...nal DIP switch 10 is ON the wheel will find its reference point then rotate continuously counter clockwise at 7 5 rpm If internal DIP switch 10 is then switched OFF without powering down the wheel wil...

Page 10: ...heel 0 8V Color 3 green Color wheel 1 2V Color 4 orange Color wheel 1 6V Color 5 magenta Color wheel 2V Color 6 blue Color wheel 2 3V Color 1 white Color wheel 2 6V Color 6 blue Color wheel 3V Color 5...

Page 11: ...Note A record of all maintenance MUST be kept in the table above indicating what maintenance was undertaken and when This MUST be dated for warranty purposes Date Maintenance Undertaken MAINTENANCE 1...

Page 12: ...ad no light output and LED power indicator on PSU is illumi nated but LED indicator on Illu minator not illuminated PSU failed Replace PSU Problem Possible Cause s Remedy Unit is dead no light output...

Page 13: ...inator Problem Possible Cause s Remedy Not responding to DMX control Dip switch no 10 is switched on Remove cover and set dip switch 10 to o DMX address not correctly set Remove cover and set correct...

Page 14: ...C Max Ambient Temperature 45 C Fan 60mm crossflow 12V Led Type White light DMX specific models only User addressable 0 10V specific models only 0 10V DC receiving LED Life 50 000 hours typical CRI 30...

Page 15: ...NOTES 7 UFO LIGHTING...

Page 16: ...dsfactory AG Gutenbergstra e 1 85737 Munchen Deutschland 49 0 9491 955880 www ufo licht de Universal Fiber Optics USA LLC 1749 Northgate Blvd Sarasota FL34234 USA 941 343 8115 www fiberopticlighting c...