S9600-28DX Hardware Installation Guide | 31 

Installation location  

The device should be installed only in a server room or computer room where access is:  

• 

Restricted to qualified service personnel or users familiar with restrictions applied to the location, 

reasons therefore, and any precautions required.  

• 

Only afforded by the use of a tool or lock and key, or other means of security, and controlled by 

the authority responsible for the location.  
 
Suitable for installation in Information Technology Rooms in accordance with Article 645 of the 
National Electrical Code and NFPA 75.

 

Summary of Contents for S9600-28DX

Page 1: ...Hardware Installation Guide S9600 28DX Open Aggregation Router R1 3...

Page 2: ...alling Fan Modules 13 7 Installing Power Supply Units 14 8 Grounding the Router 16 9 Connecting Power 18 DC Version 18 AC Version 21 10 Verifying System Operation 22 Front Panel LED 22 PSU FRU LED 23...

Page 3: ...oned into different parts of the network to perform aggregation such as in the backhaul to aggregate BBU pooling or even as a Broadband Network Gateway BNG within the central office The S9600 28DX is...

Page 4: ...r grounding 8 AWG DC power wire Crimping tool Wire stripping tool All illustrations within this document are for reference purposes only Actual objects may differ PC with terminal emulation software R...

Page 5: ...h a rack mount brackets suitable for 19 inch 48 3cm wide racks The depth of the S9600 28DX chassis is 30 inches 76 2cm without the field replaceable units FRUs and comes with adjustable check mounting...

Page 6: ...ion space requirements S9600 28DX requires 2RU 3 45 8 8cm in height 19 48 3cm in width and need a minimum reserve depth of 36 inches 91 4cm Thermal requirements S9600 28DX working temperature is 0 to...

Page 7: ...rounding Lugs 8 AWG 0 35 x 0 77 x 0 49 8 8 x 19 5 x 12 5mm 1 set 0 09lb 40 8g 1 set 3 Micro USB Cable 3 28 1000mm 1 pcs 0 05lb 24 4g 1 pcs 4 RJ45 to DB9 Female Cable 8 2438mm 1 pcs 0 23lb 105g 1 pcs 5...

Page 8: ...DC PSU 2 2lb 1 0kg AC PSU 2 6lb 1 2kg Fan module 1 1lb 498g Ground lug kit 0 03lb 15 3g Adjustable mounting rail 3 53lb 1 6kg Micro USB cable 0 05lb 24 4g RJ45 to DB9 female cable 0 23lb 105g AC powe...

Page 9: ...28DX Hardware Installation Guide 7 4 Identifying Your System S9600 28DX Overview Figure 4 PSU Overview Power supply unit PSU with 1 1 Redundancy Hot swappable field replaceable unit FRU AC Version Fig...

Page 10: ...S9600 28DX Hardware Installation Guide 8 DC Version Figure 6 Fan Overview 3 1 Redundant hot swappable field replaceable unit FRU Figure 7...

Page 11: ...rm Factor Maximum Support Distance Support Speed 0 3 SFP28 Up to 24 85mi 40km 1 10 25G 0 23 QSFP28 Up to 49 7mi 80km 40 100G 0 3 QSFP DD Up to 372 82mi 600km 100 400G The 400G QSFP DD interfaces on th...

Page 12: ...ail from the outer rail The white tab is located on the inner rail 1 3 Once the inner rail is separated push the tab located on the outer rail to unlock and slide the middle rail back Figure 9 2 Insta...

Page 13: ...be heard when the bracket is secured onto the rack Figure 11 4 Insert the Chassis to complete the installation 4 1 Pull the middle rail fully extended into lock position an audible click can be heard...

Page 14: ...S9600 28DX Hardware Installation Guide 12 Figure 12...

Page 15: ...an module Then press and hold the release tab to unlock the fan module Figure 13 2 While holding down the release tab grip the fan handle and gently pull the fan module out of the fan bay Figure 14 3...

Page 16: ...C PSU follow the same steps for installation The PSU comes pre installed and the following are instructions on how to install a new PSU Safety Notices Caution Shock hazard TO DISCONNECT POWER REMOVE A...

Page 17: ...r connector is in the correct position 4 Carefully slide the new PSU into the power bay and gently push until it is flush with the case 5 An audible click will be heard when the PSU is installed corre...

Page 18: ...e grounding lug is at the rear of the case and is covered with a protective label The following instructions are for installing the grounding lug onto the case 1 Before grounding the router ensure tha...

Page 19: ...for securing the grounding lug which is located on the rear of the router and remove the protective label Figure 20 6 Using 2 M4 screws and 2 washers provided with the package contents firmly lock the...

Page 20: ...redundancy 2 Attach the DC power cables to the lugs The UL 1015 8 AWG DC power cable not provided must be attached to a two hole lug before connecting to the PSU The following instructions are for con...

Page 21: ...er any exposed metal on the DC power cable and lug Figure 23 2 6 Use a heat source to secure the heat shrink tubing in place Allow the heat shrink tubing to cool before attaching the DC power cable An...

Page 22: ...ecure and may cause malfunctions If the torque is too much the terminal block or lug may be damaged Secure the plastic cover back onto the terminal block The figure below depicts how it should look on...

Page 23: ...ttach the power cable Locate the AC inlet connector on the PSU and plug the AC power cable 250VAC 15A IEC60320 C19 into the AC inlet connector 3 Feed AC power into the system The PSU will immediately...

Page 24: ...al reference GNSS 1PPS PTP etc Solid Amber System timing clock synchronization is in free run or holdover mode SYS OFF No power Solid Green Host CPU BMC boot complete Solid Amber Power is up but Host...

Page 25: ...r present Only 5VSB on Blinking Red 1 sec Input power cord unplugged or input power lost with a second power supply in parallel still with AC input power Blinking between Green and Red Power supply wa...

Page 26: ...e console can be connected either with the IOIO port or the micro USB port If connecting with USB drivers will need to be installed To connect the console using the IOIO port locate the port labelled...

Page 27: ...HyperTerminal Windows PC Putty or TeraTerm and configure the application The following settings are for a Windows environment other operating systems may vary Baud rate 115200 bps Data bits 8 Parity...

Page 28: ...port female connector located on the front panel of the router This USB port is a maintenance port Figure 29 Connecting a Cable to the ToD Interface 1 Connect one end of a straight through Ethernet ca...

Page 29: ...ce Connect an external GNSS antenna with an impedance of 50 ohms to the port marked GNSS ANT located on the front panel of the router Figure 31 Connecting the 1PPS Interface Connect an external 1PPS c...

Page 30: ...cable and record its respective connection Maintain a clear line of sight to the port LEDs by routing the cables away from the LEDs Before connecting anything cables transceivers etc to the router pl...

Page 31: ...ck can support it without compromising stability Otherwise personal injury and or equipment damage may result Caution This unit must be installed indoors The unit AC power supplies DC power supplies a...

Page 32: ...ded Do not defeat the ground conductor or operate the equipment without correctly grounding the equipment If there is any uncertainty about the integrity of the equipment s grounding please contact th...

Page 33: ...sonnel or users familiar with restrictions applied to the location reasons therefore and any precautions required Only afforded by the use of a tool or lock and key or other means of security and cont...

Page 34: ...www ufispace com www ufispace com...

Reviews: