background image

 

 

 

 

KIEN3016A 

Industrial Ethernet Switch 

Hardware Installation Manual 

 

 

 

 

Kyland Technology Co., LTD. 

 

 

Publication Date: Oct. 2011 

Version: V1.0 

Customer Service Hotline: (+8610) 88796676 

FAX: (+8610) 88796678 

Website: 

http://www.kyland.cn

 

E-mail: [email protected] 

No.: 1.12.02.1030-0 

 

 

Summary of Contents for KIEN3016A

Page 1: ...et Switch Hardware Installation Manual Kyland Technology Co LTD Publication Date Oct 2011 Version V1 0 Customer Service Hotline 8610 88796676 FAX 8610 88796678 Website http www kyland cn E mail support kyland biz No 1 12 02 1030 0 ...

Page 2: ...o date as possible This document is not guaranteed to be error free and we reserve the right to amend it without notice to users All rights reserved No part of this documentation may be excerpted reproduced translated annotated or duplicated in any form or by any means without the prior written permission of KYLAND Corporation Copyright 2011 KYLAND Technology CO LTD ...

Page 3: ...tie or wrap the cable to prevent fire z Power connectors and other equipment connectors should be firmly interconnected and checked frequently z Do not repair the equipment by yourself unless it is clearly specified in the manual z Please keep the equipment clean if necessary wipe the equipment with soft cotton cloth In the following cases please immediately cut off the power supply and contact ou...

Page 4: ...ace 5 3 1Front Panel 5 3 2Top Panel 7 4 Mounting 7 4 1 Mounting 7 4 2 Mounting Steps 8 5 Cable Connection 11 5 1 10 100Base T X 11 5 2 100Base FX 12 5 3 Power 13 5 4 Grounding 14 6 LED Indicators 16 7 Product Models and Accessories 17 8 Basic Features and Specifications 18 ...

Page 5: ...d compact DIN Rail industrial Ethernet switch that can be applied extensively in wind power distribution network automation subway PIS power SCADA wastewater treatment metallurgy intelligent transportation rail transit and many other industries KIEN3016A industrial Ethernet switch supports DIN Rail and panel mounting It supports IP40 protection class 3 Structure and Interface 3 1Front Panel KIEN30...

Page 6: ...rts 5 1 14 fourteen 10 100Base T X RJ45 ports 6 RJ45 port Speed LED 7 RJ45 port Link ACT LED Figure 1 Front Panel 1 z KIEN3016A 16T front panel is shown in z Figure 2 below 1 PWR1 Power 1 LED 2 PWR2 Power 2 LED 3 1 16 sixteen10 100 1000Base T X RJ45 ports 4 RJ45port Speed LED 5 RJ45portLink ACT LED ...

Page 7: ...7 Figure 2 Front Panel 2 3 2Top Panel 1 Terminal block for power input 2 Screw hole for grounding Figure 3 Top Panel 4 Mounting 4 1 Mounting z Dimension Drawing for DIN Rail Mounting Unit mm ...

Page 8: ...mm Figure 5 Panel Mounting 4 2 Mounting Steps z KIEN3016A DIN Rail Mounting The specific steps are as follows Step 1 Select the mounting position for KIEN3016A and ensure that there is adequate space Step 2 Insert the top of the DIN Rail into the spring supported slot of the ...

Page 9: ...igure 6 DIN Rail Mounting z Remove KIEN3016A from DIN Rail The specific steps are as follows Step 1 Place the screwdriver into the hole at the bottom of spring locking plate press the plate down to loosen the connection of DIN Rail and switch as shown in arrow 1 Step 2 Pull the KIEN3016A up in the direction of arrow 2 meanwhile remove the device from the DIN Rail along the direction of arrow 3 Fig...

Page 10: ...ve about 5mm of space between Step 3 Aim 4 mounting holes on KIEN3016A mounting plate at 4 fixed screws pass the screws through 4 holes with the diameter of 6 5mm Ф6 5 then slide down KIEN3016A as seen below finally screw 4 screws tightly Now the KIEN3016A should be firmly fixed to the wall or cabinet Figure 8 Panel Mounting z Remove KIEN3016A from wall or cabinet The specific steps are as follows...

Page 11: ...s or crossover cables RJ45 connectors must be attached at both ends of the cable z RJ45 port and pin number Figure 10 RJ45 Port z Pin distribution of 10 100Base T X Table 1 Pin Distribution of 10 100Base T X Pin MDI X signal name MDI signal name 1 Receiving data RD Output data TD 2 Receiving data RD Output data TD 3 Output data TD Receiving data RD 6 Output data TD Receiving data RD 8 7 6 5 4 3 2 ...

Page 12: ...raight through Cable Wiring z 100M crossover cable wiring Figure 12 100M Crossover Cable Wiring 5 2 100Base FX z 100Base FX Parameter Table Table 2 100Base FX Parameter Table Property FX FC SC ST Type Multimode Single mode Single mode Single mode Single mode Central Wavelength nm 1310 1310 1310 1550 1550 ...

Page 13: ...re 13 100M Fiber Port Wiring Note A laser is used to transmit signals in fiber cables The laser meets the requirements of level 1 laser products Routine operation is not harmful to your eyes but do not look directly at the fiber port and fiber connector when the switch is powered on 5 3 Power According to the power input requirements use a 5 08mm spacing terminal block to connect the power cable N...

Page 14: ...efinition AC wiring definition 1 PWR1 PWR1 L 2 PWR1 PWR1 N 3 Protection Ground Protection Ground 4 PWR2 PWR2 N 5 PWR2 PWR2 L z Wiring and mounting Step 1 Take the power terminal block off KIEN3016A Step 2 Insert the power cable into the terminal block and fix the power cable Step 3 Put the terminal block back to KIEN3016A with the connected cable 5 4 Grounding z Chassis grounding and power termina...

Page 15: ...ing screw and the other end of the cable is reliably grounded The cross section area of chassis grounding cable should be more than 2 5mm2 The grounding resistance requirement 5Ω The grounding part in the 5 08mm power terminal block is called surge grounding It is required to connect the chassis grounding part with the surge grounding part by an18 AWG yellow green line as seen below z 18 AWG yello...

Page 16: ...ectric voltage withstand test in order to ensure proper testing please disconnect the 18 AWG yellow green line to disable surge protection circuit that connects to surge grounding Figure 17 Disconnect 18 AWG Yellow green Line 6 LED Indicators Table 4 KIEN3016A LED Indicators ...

Page 17: ... connection in the port Blinking Network activities in the port OFF No effective network connection in the port 100Base FX LEDs Link Act ON Effective network connection in the port Blinking Network activities in the port OFF No effective network connection in the port 7 Product Models and Accessories z The specific configuration models of KIEN3016A are shown in Table 5 Table 5 KIEN3016A Configurat...

Page 18: ...310nm 40Km 60Km 100Mbps 1550nm 60Km 80Km 100Mbps z Power Requirements Power input 12VDC 9 36VDC 24VAC DC 18 50VAC 18 72VDC Power terminal 5 pin 5 08mm spacing plug in terminal block Power consumption KIEN3016A 16T 6 1W KIEN3016A 2S M 14T 6 6W z Physical Characteristics Housing Metal fanless Installation DIN Rail or Panel mounting Dimensions W H D 88mm 135mm 137mm Weight 1 2Kg z Environment Limits ...

Page 19: ...19 Storage Temperature 40 to 85 40 to 185 Ambient Relative Humidity 5 to 95 non condensing z MTBF 361000h z Warranty 5 years ...

Reviews: