background image

ExtremeCloud

 Appliance

E3120

Installation Guide

9036028-00

Published June 2019

Summary of Contents for ExtremeCloud Appliance E3120

Page 1: ...ExtremeCloud Appliance E3120 Installation Guide 9036028 00 Published June 2019 ...

Page 2: ...Networks and the Extreme Networks logo are trademarks or registered trademarks of Extreme Networks Inc in the United States and or other countries All other names including any product names mentioned in this document are the property of their respective owners and may be trademarks or registered trademarks of their respective companies owners For additional information on Extreme Networks tradema...

Page 3: ...onfiguring the Management Interface via Console Port 18 Configuring the Management Interface via the Management Port 19 Connecting the Data Ports 19 Chapter 4 Specifications 22 Chapter 5 Regulatory Information 23 Regulatory Compliance Information 23 Federal Communications Commission FCC Notice 23 Industry Canada Class A 23 CE Notice 24 Japan VCCI Voluntary Control Council for Interference Class A ...

Page 4: ...w content This is searchable text within the PDF Table 2 Text Conventions Convention Description Screen displays This typeface indicates command syntax or represents information as it appears on the screen The words enter and type When you see the word enter in this guide you must type something and then press the Return or Enter key Do not press the Return or Enter key when an instruction simply ...

Page 5: ...and service contracts download software and obtain product licensing training and certifications The Hub A forum for Extreme Networks customers to connect with one another answer questions and share ideas and feedback This community is monitored by Extreme Networks employees but is not intended to replace specific guidance from GTAC Call GTAC For immediate support 1 800 998 2408 toll free in U S a...

Page 6: ...etworks com documentation Archived Documentation for earlier versions and legacy products www extremenetworks com support documentation archives Release Notes www extremenetworks com support release notes Hardware Software Compatibility Matrices https www extremenetworks com support compatibility matrices White papers data sheets case studies and other product resources https www extremenetworks c...

Page 7: ...d personnel should perform installation procedures Caution To minimize Electrostatic Discharge ESD to the devices you must wear an antistatic wrist strap while performing the following procedures E3120 Control Panels E3120 front panel layout Label Description 1 Hard disk drive bays 2 Front video connector 3 USB 2 0 or 3 0 ports Note For USB key storage only Although the appliance has five USB conn...

Page 8: ... supply 4 Port 1 Data Port 1 1 10GbE RJ45 5 Port 2 Data Port 2 1 10GbE RJ45 6 Port 3 Data Port 3 1 10 25 40GbE QSFP28 7 Port 4 Data Port 4 1 10 25 40GbE QSFP28 8 Video connector 9 RJ45 Serial A Port 10 USB 3 0 ports 11 RMM4 NIC port not used plugged Admin Management port 1GbE RJ45 E3120 front control panel Overview ExtremeCloud Appliance E3120 8 ...

Page 9: ...LED I System status LED J Power button with integrated LED Hard Drive LED Indicator Patterns The hard drive has one LED indicator visible from the front of the system a green LED for disk activity see Front Control Panel The system status LED is a bi color indocator that shows the current health of the server which is described in the following table Overview ExtremeCloud Appliance E3120 9 ...

Page 10: ...y and process thermal control sensors Power supply failure may have occurred while redundant power supply was present There is a fault in the hard drive The appliance is unable to use all of the installed memory The battery has failed 1 Hz blinking amber Fatal or unrecoverable system hardware failure Amber color means there has been a fatal error in the system System failure is caused when Crtical...

Page 11: ...ndable management for up to 5000 access points 2 Verify that the contents of the box include the E3120 appliance and that the included hardware matches the package contents 3 Review the Safety Guidelines Verifying the Box Contents Before you install the E3120 appliance make sure that you have all the necessary parts 1 Verify that the box contains the following items Table 5 E3120 box contents Quan...

Page 12: ...g it on the rack handles A key lock allows you to lock the bezel in place to restrict access to the controls on the front panel You can monitor the system status indicators with the bezel in place 1 Lock the right end of the front bezel to the rack handle see label A 2 Push the front bezel until the left end clicks into place see label B Figure 1 Attaching the front bezel 3 Lock the bezel if neede...

Page 13: ...t with a second PS in parallel still with AC input power Amber Power supply warning events where PS continues to operate high temperature high power high current and slow fan 1 Hz blinking amber Power supply critical event causing a shutdown failure OCP OVP and fan fail Amber Power supply firmware update 2 Hz blinking green Installing a Redundant Power Supply To install a power supply module 1 If ...

Page 14: ...igure 2 Installing a power supply module 4 Connect the unit to a power source Removing a Power Supply To remove a power supply module 1 Detach the power supply cord from the power supply module that needs to be removed Hardware Installation ExtremeCloud Appliance E3120 14 ...

Page 15: ... Handle B Latching tab Replacing a Power Supply To replace a power supply 1 Detach the power supply cord from the power supply module that needs to be removed 1 Release the slider strap on the power supply cord by pushing down the slider tab 2 Pull the slider strap over the power supply cord 3 Remove the power cord from the power supply module Hardware Installation ExtremeCloud Appliance E3120 15 ...

Page 16: ...ove and replace only one power supply module at a time in a system that is powered on 3 Refer to Installing a Redundant Power Supply on page 13 to install the replacement power supply module into the power supply bay Connecting to a Power Source Locate the power cord retention strap from the AC power cord bracket and cable clamp kit To connect the E3120 unit to a power source Hardware Installation...

Page 17: ...ese two power supplies combine and create an optional redundant power supply 4 Lock the retention strap to the power cord by pulling the slider strap over the power cord Figure 4 Attaching the power cord to the appliance 2 Plug the other end of the power cords into grounded electrical outlets or to separate power sources such as an uninterrupted power supply UPS or a power distribution unit PDU 3 ...

Page 18: ...ection Be sure that your serial connection is set properly 115200 baud 8 data bits 1 stop bit Parity none Flow control none 3 Using the console session perform the following At the password prompt enter user as admin For the initial password enter abc123 Press ENTER 4 Read the configuration script paragraph carefully The configuration script will walk you through configuring the following Admin Pa...

Page 19: ...ng the appliance on the network 1 Connect a laptop to the management port of the appliance 2 Configure the Ethernet port of the laptop with a statically assigned unused IP address in the 192 168 10 0 24 subnet 3 Open a web browser and in the browser address bar type https 192 168 10 1 5825 192 168 10 1 is the default IP address on the appliance management port The ExtremeCloud Appliance logon scre...

Page 20: ...e the transceiver from its packaging If there is a protective dust cover on the transceiver connector do not remove it at this time 2 Hold the transceiver so that the connector will seat properly 3 Carefully align the transceiver with the port slot 4 Push the transceiver into the port slot until it clicks and locks into place Connecting Cables to Transceiver Ports To connect cables to transceiver ...

Page 21: ...ps 1 Gbps Solid Green 10000 Mbps 10 Gbps Link Activity Left Off No link Solid Green Active link Blinking Green Data traffic activity QSFP28 Port LEDs Data Ports 3 and 4 LED Color and State Description Status Indication Off Physical link has not been established Solid Yellow Active physical link Blinking Amber 4Hz Problem with the physical link Solid Green Valid logical data activity link with no a...

Page 22: ...hysical Specifications Dimensions Length 31 25 Width 17 25 Height 1 7 Environmental Specifications Operating Temperature 5 C to 40 C 32 F to 104 F Relative Humidity 0 to 95 non condensing ExtremeCloud Appliance E3120 22 ...

Page 23: ... s instruction manual may cause harmful interference to radio communications Operation of this product in a residential area is likely to cause harmful interference in which case you will be required to correct the interference at your own expense This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference...

Page 24: ...Voluntary Control Council for Interference Class A ITE This is a class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take corrective actions BSMI EMC Statement Taiwan This is a class A produ...

Page 25: ...complies with the requirements of Directive 2011 65 EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment Regulatory Information ExtremeCloud Appliance E3120 25 ...

Page 26: ...rted municipal waste It must be collected and treated separately 3 It has been determined by the European Parliament that there are potential negative effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment 4 It is the users responsibility to utilize the available collection system to ensure WEEE is properly treated For...

Page 27: ...ort LEDs E3120 LEDs LED Patterns 21 E3120 Power Source Power Source Power Connection 16 E3120 Power Supply Power Supply Options 12 E3120 Specifications Product Specifications Physical Specifications Environmental Specifications 22 F FCC Notice Federal Communications Commission Regulatory Information 23 H Hardware Installation 11 I Industry Canada Notice 23 L LEDs LED Patterns LED Indicator Pattern...

Reviews: