Version 1
17
TO CHARGE THE UP3000:
•
The recharger has a 5-pin mini USB plug that connects to the 5-pin mini USB jack on the
Ultraprobe.
•
Plug the recharger into an electric outlet and then place the 5-pin mini USB plug into the 5-
pin mini USB jack on Ultraprobe 3000.
•
The LED on the charger will be red when charging and then turn green when fully charged.
Charging will take about one hour.
•
Remove the charger from the electric outlet when fully charged
WARNING
:
Use the supplied UE Systems recharger
only
. Use of unauthorized rechargers will void
the warranty and may damage the battery and or instrument.
WARBLE TONE GENERATOR (UE-WTG-1):
Turn Tone Generator on by selecting either "LOW" for a low amplitude signal (usually
recommended for small containers) or "HIGH" for high amplitude. In high, the Warble Tone
Generator will cover up to 4,000 cubic feet (121.9 cu. meters) of unobstructed space.
When the Tone Generator is on, a red light (located below the recharge jack in the front) flickers.
Place the Warble Tone Generator within the test item/container and seal or close it. Then scan the
suspect areas with the Scanning Module in the Ultraprobe and listen for where the "warble"
ultrasound penetrates .As an example, if the item to be tested is the seal around a window place
the Warble Tone Generator on one side of the window, close it and proceed to scan on the
opposite side.
To test the condition of the Warble Tone Generator battery, set to the LOW INTENSITY position
and listen to the sound through the Ultraprobe at 40 kHz. A continuous warbling sound should be
heard. If a "beeping" is heard instead, then a full recharge of the
Warble Tone Generator is indicated.
TO CHARGE THE WARBLE TONE GENERATOR:
Plug recharger cable into recharger jack on the Warble Tone Generator and then plug the
recharger into an electric outlet. Make sure that the LED on the charger is lit when recharging.
The LED turns OFF when the battery is charged.