VISION
UDOO VISION User Manual - Rev. First Edition: 1.0 - Last Edition: 1.0 - Author: A.R. - Reviewed by M.B. Copyright © 2021 SECO S.p.A
52
4.3.15.2
Reset Causes Handling submenu
4.3.15.3
Super IO Configuration submenu
Menu Item
Options
Description
Reset Button Pressed
Happened / Not
happened
If Reset button is pressed, this parameter will automatically be set as Happened
Clear from log
Enabled / Disabled
If Reset button is pressed and Clear from log parameter is enabled, this will require system reset
WDT Timeout Expired
Happened / Not
happened
If Watchdog Timer (WDT) timeout has expired, this parameter will automatically be set as Happened
Clear from log
Enabled / Disabled
If Watchdog Timer (WDT) timeout has expired, and Clear from log parameter is enabled, this will require
system reset
Power Failure
Happened / Not
happened
If a Power Failure occurs, this parameter will automatically be set as Happened
Clear from log
Enabled / Disabled
If a Power Failure occurs and Clear from log parameter is enabled, this will require system reset
E.C. soft reset
Happened / Not
happened
If the Embedded Controller (E.C.) is reset, this parameter will automatically be set as Happened
Clear from log
Enabled / Disabled
If the Embedded Controller (E.C.) is reset and Clear from log parameter is enabled, this will require system
reset
Menu Item
Options
Description
Serial Port 1
Enabled/Disabled
Enables or Disables Serial Port # 1
Address
0X3F8, 0x3E8, 0x2F8,
0x2F0, 0x2E8, 0x2E0,
0x2A8, 0x2A0, 0x288,
0x280
Select the Base address for Serial Port #1, if enabled.
IRQ
3 / 4 / 5 / 6 / 7 / 10 / 11
/ 14 / 15
Select the IRQ line to assign to Serial Port #1, if enabled.
Serial Port 2
Enabled/Disabled
Enables or Disables Serial Port # 2
Address
0X3F8, 0x3E8, 0x2F8,
0x2F0, 0x2E8, 0x2E0,
0x2A8, 0x2A0, 0x288,
0x280
Select the Base address for Serial Port #2, if enabled.