11
4. Remove the tension coil springs (2 locations) provided around the heater
Remove these
two springs.
5. Press the INCHING switch to rotate the main spindle to cause the heater to go to the top dead
point.
Tape guide
Tape guide
6. Turn off the power switch.
7. While opening the tape guide by hand, take out the heater section.