Installation Instructions
SECTION EIGHT
Siting the Appliance Continued
CLASS TWO FABRICATED METAL
A double-walled or insulated metal flue box built to the requirements of BS 715 with an insulated flue
having a minimum diameter of 125 mm (5 ins) and a minimum effective overall height of 3 metres (10
ft).
Note:
Dampers or register plates must not restrict any of the above flues. The flue must only service
a single appliance and not have any branches or traps, which may impede the natural draught. If a
terminal is fitted it must be suitable for the purpose.
SURROUNDS
The fire can be fitted in either a conventional hearth (i.e. tile fireplace etc), plinth mounted, in a fire
surround, or a hole-in-the-wall installation. If a heaths or plinths is used it MUST be non-combustible.
Purpose built superimposed fire-resistant hearths and back panels, specified as suitable by the
manufacturers, may be used, or a suitable proprietary fire surround with a 150
o
C minimum rating.
The trim and fret supplied with the appliance determines the type of installation that can be
accommodated. Check table below for installation compatibility.
IMPORTANT NOTE when the fire is installed without a fireplace or non combustible back panel any
wall surface or covering that comes in contact with the appliance and is not non combustible must be
removed.
Care should be taken to prevent any damage being caused to surrounding soft furnishings or
decoration e.g. many wall coverings may become discoloured if placed too close to the appliance.
FIREPLACE OPENING
The front face and the base of the fire opening must be flat to ensure that a good seal is formed
between the rear and base of the appliance and the chimney to avoid any reduction of natural
draught.
400-456mm
560-580mm
320mm
Min
Hearth or Plinth
Can be used with
Standard four sided
trim option.
Floor
X
This area behind the trim/fascia
must be clear of combustible
material and be flat to
accommodate the seal.
When installing the standard four sided trim
option this area at the base of the opening
must be clear of combustible material and be
flat to accommodate the seal.
TRIM / FACSIA DIMENSION ARE
SPECIFIED IN THE APPLIANCE DATE
SECTION.