13
LT---- (iss -- --/--)
UC Living Arranmore SC
Installation Instructions
SECTION SIX
Appliance Data
NATURAL GAS
PROPANE GAS
Gas Type:
CATEGORY I 2 H
CATEGORY I 3 P
Gas Pressure:
20 mbar +/- 1.0mbar
37 mbar +/- 1.0mbar
Pressure Test Point Location:
Gas inlet elbow
Gas Input:
5.5 kW Gross (Max.)
5.1 kW Gross (Max.)
2.4kW Gross (Min.)
2.7 kW Gross (Min.)
Injectors:
Mk 360
Mk 116
Oxy pilot:
9044
9221
Gas Connection:
8mm compression: semi-rigid or rigid
Data Badge Location:
Located on left hand of appliance behind trim or fascia
Appliance Dimensions
NOTE: The efficiency of this appliance has been measured as specified in BS7977-1 2002 and the
result is 80.0%. The gross calorific value of the fuel has been used for this efficiency calculation.
GasTec have certified the test data from which it has been calculated. The efficiency value may be
used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating of dwellings.
Please note:
The restrictor fitted to the appliance is there to achieve the maximum efficiency. This,
however, may require removal where a flue is underperforming.
When unpacking the appliance please check the following items are included:
Fuel Bed:
Coal or Pebble:
Wire Fixing Kit (Including magnets & restrictor elbow), Foam sealing strip, Owners Manual,
Trim and Fret or Fascia.
SECTION SEVEN
Regulations and Warnings Continued
This appliance must only be installed in Great Britain or Ireland.
Confirm that the appliance is suitable prior to installation (
G20 for natural gas or G31 for propane
gas
) (refer to data badge on base of appliance).
Note: the appliance should only be used on the
appropriate gas specified. It is not suitable for conversion from one gas to the other.
GB (Great Britain)
This fire does not normally require purpose build ventilation.
IE (Ireland)
Permanent ventilation must comply with the current edition of IS813.
In GB
,
(Great Britain)
It is the law that all gas appliances must be installed by a competent person; i.e. a GAS SAFE
registered installer, in accordance with the Current Gas Safety (Installation And Use) Regulations
(as amended), all relevant parts of the local and national building regulations and all relevant
recommendations of the following British Standards. Failure to do so could lead to prosecution.